Plan Review Notes
Plan Review Notes For Permit 16031217
Permit Number 16031217
Review Stop P
Sequence Number 1
Notes
Date Text
2016-04-04 05:39:501) A TIME SWITCH IS REQD. ON THE HEATER. 2014
 FBC-ENERGY SEC.R403.9.2 TIME SWITCHES.
 TIME SWITCHES OR OTHER CONTROL METHOD THAT CAN
 AUTOMATICALLY TURN OFF AND ON HEATERS AND PUMPS
 ACCORDING TO A PRESET SCHEDULE SHALL BE INSTALLED ON
 ALL HEATERS AND PUMPS. HEATERS, PUMPS AND MOTORS THAT
 HAVE BUILT IN TIMERS SHALL BE DEEMED IN COMPLIANCE WITH
 THIS REQUIREMENT.
  
 EXCEPTIONS:
  
 1. WHERE PUBLIC HEALTH STANDARDS REQUIRE 24-HOUR PUMP
 OPERATION.
  
 2. WHERE PUMPS ARE REQUIRED TO OPERATE SOLAR- AND
 WASTE-HEAT-RECOVERY POOL HEATING SYSTEMS.
  
 3. WHERE PUMPS ARE POWERED EXCLUSIVELY FROM ON-SITE
 RENEWABLE GENERATION.
  
 2) A VAPOR RETARDANT POOL COVER IS REQD. PER 2014
 FBC-ENERGY SEC.R403.9.3.
 3) THE HEATER SHALL BE PROVIDED WITH A MEANS OF
 RETAINING WATER IN THE HEATER WHEN THE PUMP IS NOT IN
 OPERATION.
 R4501.14.2 WATER RETENTION.
 IF A HEATER IS NOT EQUIPPED OR DESIGNED FOR AN APPROVED
 PERMANENT BYPASS OR ANTISIPHON DEVICE, AN APPROVED
 PERMANENT BYPASS OR ANTISIPHON DEVICE SHALL BE
 INSTALLED TO PROVIDE A POSITIVE MEANS OF RETAINING
 WATER IN THE HEATER WHEN THE PUMP IS NOT IN OPERATION.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  
  
  