| Plan Review Notes For Permit 16031043 |
| Permit Number |
16031043 |
|
| Review Stop |
E |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2016-04-13 09:41:27 | INITIAL ELECTRICAL PLAN REVIEW | | | | | | APPLICABLE CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70- 2011 | | | COMMENTS: | | | | | | 1. PROVIDE A GENERAL NOTE TO COMPLY WITH PART 2 OF NEC | | | ARTICLE 680 | | | 2. PLEASE PROVIDE SPECIFICATION SHEET FOR ALL | | | ASSOCIATED POOL EQUIPMENT. FBC 107.3.5 | | | 3. SHOW THE BONDING ARRANGEMENTS TO COMPLY WITH NEC | | | 680.26 FOR ALL. | | | 4. PROVIDE GFCI PROTECTION FOR POOL PUMPS, SHOW ON | | | PANEL BOARD SCHEDULE PER NEC 680.21C | | | 5. PROVIDE A NOTE TO COMPLY WITH NEC 680.41- EM SWITCH | | | SHUTOFF FOR SPA. | | | 6. FURTHER COMMENTS MAY FOLLOW UPON RESUBMITTAL. FEEL | | | FREE TO CONTACT ME AT THE NUMBER LISTED BELOW SHOULD | | | YOU HAVE ANY QUESTIONS OR CONCERNS. | | | | | | VALENTINO PEREZ | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6717 | | | [email protected] | | | |
|