2016-03-22 18:45:10PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE PROJECT IS LOCATED ADJACENT TO A LAKE AND THE
 EXPOSURE D SURFACE ROUGHNESS PREVAILS IN THE UPWIND
 DIRECTION FOR AT LEAST 5,000 FEET. THEREFORE EXPOSURE D
 APPLIES TO YOUR PROJECT. THE RAS 117 CALCULATIONS ARE
 BASED ON EXPOSURE C. SUBMIT NEW CALCULATIONS FOR
 EXPOSURE D.
  
 2) THE RAS 117 ARE REQUIRED TO HAVE THE FLORIDA
 ENGINEER'S SEAL AND ORIGINAL HANDWRITTEN SIGNATURE,
 COPIES OR OTHER FACSIMILES ARE NOT ACCEPTABLE. FAC
 61G15 - 23.002 DIGITAL SIGNATURES ARE ONLY ACCEPTABLE
 FOR ELECTRONICALLY TRANSMITTED PLANS AND DOCUMENTS.