Plan Review Notes
Plan Review Notes For Permit 16030858
Permit Number 16030858
Review Stop B
Sequence Number 1
Notes
Date Text
2016-04-06 10:48:50BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16030858
 ADD: 255 EVERNIA ST. SUITE: MU-4
 CONT: COMPLETE PROPERTY MANAGEMENT
 TEL: 561-626-2778
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. APRIL 06/2016
 ACTION: DENIED
  
 1) SHEET LS.01 IT APPEARS THIS TENNANT SPACE IS A MIXED
 USE OCCUPANCY WITH OVER 50 OCCUPANTS.
 THE DESIGNER OF RECORD INDICATES:
 42 SEATS
 04 EMPLOYEES
 05 OCCUPANTS MEZZANINE LEVEL
 -----------
 51 OCCUPANTS TOTAL
  
 THE PLANS ONLY SHOW 40 SEATS, THERE IS NO SQUARE
 FOOTAGE TAKEN FOR THE KIOSK, FIGURED 25 SQ. FT. PER
 KIOSK X 7= 175 SQ. FT/ 30= 6 PLUS THE 2 KITCHEN PLUS
 THE 500 SQ. FT. MEZZANINE/ 100= 5 OCCUPANTS.
 40 SEATS
 06 KIOSK
 02 KITCHEN
 05 MEZZANINE
 ---------------
 53 OCCUPANTS.
  
 WHEN OVER 49 OCCUPANTS (2) EXITS WILL BE REQUIRED. 2014
 FBC-B TABLE 1015.1.
  
 2) IT IS ONLY ASSUMED THE MEZZANINE LEVEL IS GOING TO
 BE A BUSINESS OCCUPANCY.SHEET LS.02 INDICATES AN
 EXISITNG OFFICE, IS THIS STILL BE THE SAME USE? IF THE
 USAGE CHANGES TO A HIGHER OCCUPANT LOAD THEN VERTICAL
 ACCESSIBILITY WILL BECOME A ISSUE,
 2014 FBC-ACCESIBLITY CODE 201.1.1 MAYBE EXEMPT UNDER
 (3) OCCUPIABLE SPACES THAT ARE NOT OPEN TO THE PUBLIC
 AND HOUSE NOT MORE THAN 5 PERSONS.
  
 3) NEITHER THE LIFE SAFETY PLANS OR 1ST FLOOR PLANS
 SHOW COMPLIANCE WITH THE 2014 FBC-ACCESSIBILITY CODE;
 3A) 226.1 WHERE DINING SURFACES ARE PROVIDED FOR THE
 CONSUMPTION OF FOOD OR DRINK, AT LEAST 5 PERCENT OF THE
 SEATING SPACES AND STANDING SPACES AT THE DINING
 SURFACES SHALL COMPLY WITH 902.
  
 2B) SHOW ACCESSIBLE SEATING AT TABLES AS WELL AS THE
 COUNTER. 226.2 DISPERSION. DINING SURFACES AND WORK
 SURFACES REQUIRED TO COMPLY WITH 902 SHALL BE DISPERSED
 THROUGHOUT THE SPACE OR FACILITY CONTAINING DINING
 SURFACES AND WORK SURFACES.
  
 2C) 902.2 CLEAR FLOOR OR GROUND SPACE. A CLEAR FLOOR
 SPACE COMPLYING WITH 305 POSITIONED FOR A FORWARD
 APPROACH SHALL BE PROVIDED. KNEE AND TOE CLEARANCE
 COMPLYING WITH 306 SHALL BE PROVIDED.
  
 2D) 902.3 HEIGHT. THE TOPS OF DINING SURFACES AND WORK
 SURFACES SHALL BE 28 INCHES (710 MM) MINIMUM AND 34
 INCHES (865 MM) MAXIMUM ABOVE THE FINISH FLOOR OR
 GROUND.
  
 3) SHEET P.01 THE NEW RESTROOM DETAILS SHOW THE GRAB
 BARS DIMENSIONED 33-36 INCHES CENTERLINE FROM FINISH
 FLOOR. THIS IS A CHANGE IN THE 2014 FBC-B NOTE THE GRAB
 BARS ARE MEASURED FROM FINISH FLOOR TO THE TOP OF THE
 GRASPING SURFACE NOT CENTERLINED. 2014
 FBC-ACCESSIBILITY CODE 609.4 POSITION OF GRAB BARS.
  
 4) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  
  
  
  
  
  