Plan Review Notes
Plan Review Notes For Permit 16030671
Permit Number 16030671
Review Stop B
Sequence Number 1
Notes
Date Text
2016-03-25 15:07:141ST REVIEW: FBC 2014 5TH ED
 CHRISTOPHER S. THROOP, C.B.O.
 BLDG. PLANS EXAMINER ? PX3169
 (561) 805-6718
 [email protected]
  
 GENERAL NOTES:
 PLANS INCLUDE PERGOLA, GARAGE & DECK.
 1. VALUE APPEARS LOW FOR SCOPE OF WORK. PROVIDE COPY OF
 ESTIMATE OR MATERIAL RECEIPTS.
 2. PROVIDE SITE PLAN TO VERIFY SETBACKS. (SEE ZONING
 COMMENTS).
 3. PROVIDE WIND SPEED CALCULATIONS FOR PERGOLA, GARAGE
 AND DECK.
 4. STATE GOVERNING CODES ON PLANS. (FBC 2014 5TH ED.,
 NEC 2011,ETC.).
 DECK NOTES:
 5. PROVIDE DETAIL FOR POST BASE FOUNDATION. PG. A2.0
 6. SPECIFY FLASHING TYPE. PG. A2.0
 7. SPECIFY POST CAP ATTACHMENT FASTENER PER DETAIL 3,
 PG. A2.1
 8. STAIR RISER HEIGHT NOT TO EXCEED 3/8" DEVIATION PER
 DETAIL 6, PG. A2.1.
 9. PROVIDE SPACING FOR 1/2" DIAMETER THRU BOLTS @
 LEDGER BOARD PER DETAIL 5, PG. A2.I.
 10.SPECIFY WOOD SPECIES AND GRADE FOR DECK JOISTS,
 LEDGERS AND BEAMS TO VERIFY ALLOWBLE SPANS. PG. A2.1.
 11. OVERALL DECK WIDTH OF 19FT.-0" EXCEEDS LUMBER
 LENGTH IN MATERIAL SCHEDULE. PROVIDE DETAIL FOR
 SPLICING AND BEARING OF DECK BEAMS. PG. A2.0.
 PERGOLA NOTES: INSUFFECIENT INFORMATION TO COMPLETE
 REVIEW. ADDITIONAL REVIEW NOTES POSSIBLE.
 12. PROVIDE SCHEDULE OF MATERIALS. PG. A2.2.
 13. PROVIDE POST BASE DETAIL. PG. A2.2.
 14. PROVIDE CONNECTOR SCHEDULE AND FASTENER SCHEDULE
 FOR ALL CONNECTIONS. PG. A2.2.
 GARAGE NOTES:
 15. PROVIDE STRUCTURAL DRAWINGS FOR FOUNDATION, CMU
 WALLS AND BEAMS. PG. A1.4.
 16. PROVIDE DETAIL FOR BEAM TO TRUSS CONNECTION. PG
 A1.4.
 17. PROVIDE ROOF SHEATHING FASTENER SCHEDULE BASED ON
 WIND SPPED CALC'S.
 18. PROVIDE PRODUCT APPROVALS FOR EXTERIOR DOOR,
 OVERHEAD DOOR AND ROOF SYSTEM PRODUCTS.
 19. ROOFING PERMIT REQUIRED.
  
 FBC 109.3 BUILDING PERMIT VALUATION. FOR PERMITTING
 PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE
 TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL,
 ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH,
 RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES,
 MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY
 LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST
 PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS
 SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY
 INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT
 VALUATION SHALL BE SET BY THE BUILDING OFFICIAL.
 FAILURE TO PROVIDE DOCUMENTATION OF ESTIMATED COSTS MAY
 DELAY THE APPLICATION PROCESS.
  
 FBC 107.3.5.3 ? PROVIDE A SITE PLAN TO DEMONSTRATE
 SETBACKS AND BUILDING SEPARATION.
  
 FBC 107.3.5.3 - PROVIDE WIND DESIGN LOADS/DESIGN
 PRESSURES PURSUANT TO FBC-R301.2.
  
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE
 DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES,
 RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING
 OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL
 CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE,
 AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS
 ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH
 INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES
 SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE
 TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE
 FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS,
 SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE
 NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE
 DESIGN. (SEE ALSO SECTION 107.3.5).
  
 FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING AND DOOR SUBMITTALS.
  
  
  