Plan Review Notes
Plan Review Notes For Permit 16030429
Permit Number 16030429
Review Stop B
Sequence Number 2
Notes
Date Text
2016-04-04 12:27:00BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16030429
 ADD: 5444 N. HAVERHILL RD. UNIT:D
 CONT: CCK CONSTRUCTION
 TEL: 586-907-5909
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: MONDAY APRIL 04/2016
 ACTION: DENIED
  
 1) 2ND REVIEW. NOTE THE PLANS WERE NOT UPLOADED
 PROPERLY TO BE VERSIONED. ALL PLANS FROM THE 1ST
 SUBMITTAL FOR ALL TRADES WILL NEED TO BE VOIDED, SINCE
 THEY WILL PRINT AT THE SAME TIME AS THE APPROVED PLANS.
 THE 12 FOOT WIDE FOUNDATION PLAN(SHEET A4) THAT WAS
 SUBMITTED AS A ELECTRONIC REVIEW DOES NOT HAVE THE
 PLANS SIGNED ELECTRONICALLY AS REQUIRED BY FLORIDA
 ADMINISTRATIVE CODE 61G1-16.005. PROCEDURES FOR
 DIGITALLY SIGNING AND SEALING AND FOR ELECTRONICALLY
 TRANSMITTING PLANS, SPECIFICATIONS, REPORTS OR OTHER
 DOCUMENTS.
  
 COMMENT FROM 1ST REVIEW.THE 12 FOOT WIDE FOUNDATION
 PLAN IS NOT SIGNED NOR SEALED BY THOMAS MILTON
 ARCHITECT. PLANS, SPECIFICATIONS, REPORTS OR OTHER
 DOCUMENTS PREPARED BY THE DESIGN PROFESSIONAL AND BEING
 FILED FOR PUBLIC RECORD SHALL HAVE THE SIGNATURE AND
 SEAL OF THE DESIGN PROFESSIONAL AFFIXED TO THE
 DOCUMENT. FL ADMIN CODE 61G16.003 ARCHITECTS.
  
 2A) PROVISO: RESPONSE INDICATES THE MODULAR UNIT :D IS
 FOR CONSTRUCTION PERSONNEL ONLY NOT AN ACCESSIBLE UNIT.
 THIS MODULAR BUILDING DOES NOT PROVIDE AN ACCESSIBLE
 RAMP? 2014 FBC-ACCESSIBILITY CODE 405, 1-10.
  
 2B) THE STAIR PLANS SHEETS 7 OF 7 SIGNED BY KEVIN FINN
 P.E. WERE SIGNED ON THE ORIGINAL SHEETS BUT THE
 ELECTRONIC VERSION DOES NOT HAVE AN ELECTRONIC
 SIGNATURE AS REQUIRED BY 61G15-23.003 FOR ENGINEERS.
  
 3) SHEET A4 INDICATES THAT IS THE DESIGNER OF RECORD
 FOR THIS SHEET, NOT SIGNED NOR SEALED. PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS PREPARED BY
 THE DESIGN PROFESSIONAL AND BEING FILED FOR PUBLIC
 RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE DESIGN
 PROFESSIONAL AFFIXED TO THE DOCUMENT. FL ADMIN CODE
 61G16.003 ARCHITECTS.
  
 IF THE ARCHITECT AND ENGINEER DO NOT HAVE TTHE
 CAPABILITIES FOR ELECTRONIC SIGNATURES ORIGINAL SIGNED
 AND SEALED PLANS , PAPER WITH ORIGINAL SEALS AND
 SIGNATURES CAN BE SUBMITTED, WE WILL KEEP THE ORIGINALS
 FOR THE RECORD RETENSION PROGRAM.
  
 4) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  