| Date |
Text |
| 2016-06-06 18:09:05 | JOB PERMIT NUMBER: 16030072 |
| | JOB ADDRESS: 618 49TH STREET |
| | WEST PALM BEACH FLORIDA 33407 |
| | DATE: JUNE 6 2016 |
| | ELECTRICAL PLAN REVIEW COMMENTS |
| | |
| | THE PLANS FOR THE ABOVE MENTIONED PERMIT APPLICATION |
| | HAVE BEEN REVIEWED FOR COMPLIANCE WITH THE EDITION OF |
| | THE NEC, (NATIONAL ELECTRICAL CODE) AND THE FBC, |
| | (FLORIDA BUILDING CODE) AS WELL AS THE CITY OF WEST |
| | PALM BEACH AMENDMENTS IN EFFECT AT THE TIME OF |
| | SUBMITTAL. BELOW IS A LIST OF THE DEFICIENCIES NOTED. |
| | |
| | - THE SCOPE OF WORK DEFINES THIS AS AN ADDITION TO THE |
| | EXISTING DWELLING UNIT THEREFORE ELECTRICAL DRAWINGS |
| | MUST PROVIDE THE MINIMUM PLAN CRITERIA. FBC 107 |
| | - SMOKE ALARMS AS PER RESIDENTIAL CODE SECTIONS 314 & |
| | 315. |
| | - RECEPTACLE OUTLET SPACING AND LIGHTING OUTLET |
| | REQUIREMENTS IN ACCORDANCE WITH NEC 210.52 & 210.70 |
| | - NEC 406.11 TAMPER-RESISTANT RECEPTACLES IN DWELLING |
| | UNITS. IN ALL AREAS SPECIFIED IN 210.52, ALL 125-VOLT, |
| | 15 AND 20 AMPERE RECEPTACLES SHALL BE LISTED TAMPER |
| | RESISTANT RECEPTACLES. |
| | - NEC 210.12B - OUTLETS TO BE AFCI PROTECTED. |
| | - ELECTRIC SERVICE RISER WITH WIRE SIZES, CONDUIT |
| | DETAIL AND GROUNDING DETAIL. COMPLETE LOAD |
| | CALCULATIONS, PANEL SCHEDULES AND SHOW CIRCUITS ON |
| | FLOOR PLAN. |
| | - AN ELECTRICAL SUB-PERMIT SHALL BE ISSUED BY THE |
| | ELECTRICAL CONTRACTOR PERFORMING THE WORK. |
| | |
| | PLEASE REVISE YOUR DRAWINGS TO REFLECT THE ABOVE |
| | MENTIONED DEFICIENCIES. |
| | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR |
| | RE-SUBMITTAL, YOU ARE REQUIRED TO PROVIDE A RESPONSE |
| | LETTER (NARRATIVE) ADDRESSING EACH ITEM ALONG WITH THE |
| | STANDARD CITY RE-SUBMITTAL FORM. THE NARRATIVE SHOULD |
| | INCLUDE THE PLAN REVIEWER?S COMMENTS AND YOUR RESPONSE |
| | OR ACTION TO SAME. ADDITIONALLY, PLEASE INSERT |
| | CORRECTED PAGES INTO THE SUBMITTAL AND LEAVE THE |
| | PREVIOUSLY REVIEWED SHEETS FOR COMPARISON. |
| | CLOUDING THE CHANGES WILL BE GREATLY APPRECIATED. |
| | |
| | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO |
| | CONTACT ME DIRECTLY. |
| | |
| | FBC 2014 5TH ED. NEC 2011 |
| | MARIO VALDES |
| | ELECTRICAL PLAN EXAMINER |
| | 561-805-6713 |
| | [email protected] |
| | |