| Date |
Text |
| 2016-03-24 11:35:21 | BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 16030026 |
| | ADD: 425 24TH ST. |
| | CONT: CLEAR SPAN STRUCTURES, LLC |
| | TEL: 561-803-8100 |
| | E-MAIL: [email protected] |
| | |
| | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| | FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: THURS. MARCH 24/ 2016 |
| | ACTION: DENIED |
| | |
| | BUILDING TYPE; III-A (PROTECTED)/ SPRINKLERED. |
| | PLEASE NOTE SHEETS LS-1 & A1 SHOWS PHASE III WITH A |
| | CONTINUATION OF WORK FROM PHASE II COVERED UNDER PERMIT |
| | 12030123 (2007 FBC-B). UNDER THIS EDITION OF THE FBC |
| | CORRIDORS HAD TO BE FIRE RATING SO THE PHASE III PERMIT |
| | WILL CONTINUE THE 1 HOUR FIRE RATING OF THE NEW |
| | CORRIDORS. |
| | |
| | 1) SHEET A1: |
| | 1A) PLEASE NOTE THE NEW FIRE RATED CORRIDOR WALLS ARE |
| | SHOWN WITH WALL TAGS B1 & B2 WITH THE EXCEPTION OF THE |
| | CORRIDOR WALL THAT SEPARATES TO ROOM 315. THIS NEW WALL |
| | DOES NOT SHOW AS A 1 HOUR FIRE RATED WALL. PLEASE SEE |
| | WALL TYPES ON SHEET A1, THIS WALL DOES NOT HAVE A WALL |
| | IDENTIFICATION TAG. 107.2.1.3 ADDITIONAL INFORMATION IS |
| | REQUIRED. |
| | |
| | 1B) PLEASE SEE THE DOOR SCHEDULE ON SHEET A-9, THE DOOR |
| | SCHEDULE DOES NOT EVEN HAVE A COLUMN INDICATING FIRE |
| | RATED DOORS. 2014 FBC-B TABLE 716.5. |
| | |
| | 1C) PLEASE NOTE SHEET A9 VERSES SHEET M-1, SHEET M-1 |
| | SHOWS DUCTS CROSSING THE 1 HOUR FIRE RATED WALLS |
| | WITHOUT THE BENEFIT OF FIRE DAMPERS SEE 2014 FBC-B |
| | 717.1. ALSO SEE NOTES FROM THE MECHANICAL REVIEWER FOR |
| | NUMEROUS CODE VIOLATIONS INVOLVING DUCTS PENETRATING |
| | THE 1 HOUR FIRE RATED WALL. |
| | |
| | 2) SHEET M1 NOTE # 2 INDICATES THE USE OF A 14 X 14 |
| | INCH CURB MOUNTED GRAVITY INTAKE VENTILATOR GRENNHECK |
| | MODEL GRSR-16. SHEET M5 DETAIL 5 INDICATES A CUT |
| | SECTION OF THE INSTALLATION DETAIL. NOTE IN THE DETAIL |
| | INDICATES SEE ARCHITECTURAL & STRUCTURAL PLANS FOR CURB |
| | FRAMING AND ATTACHMENT TO ROOF. |
| | |
| | 2A) , 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA |
| | DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 |
| | (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS |
| | THAT WILL REQUIRE PRODUCT APPROVALS: |
| | (31) (D) ROOFING PRODUCTS AND ASSEMBLIES/ CURBS/ INTAKE |
| | AND ROOF TOP EXHAUST FANS. |
| | |
| | 2B) 107.3.4.1 THOSE PRODUCTS WHICH ARE REGULATED BY DCA |
| | RULE 9N-3 SHALL BE REVIEWED AND APPROVED IN WRITING BY |
| | THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR |
| | JURISDICTIONAL APPROVAL. |
| | |
| | 2C) PLEASE PROVIDE DETAILS FOR THE FRAMING REQUIRED |
| | AROUND THE NEW OPENING IN THE ROOF SYSTEM. THIS FRAMING |
| | SHOULD TIE BACK INTO THE MWFRS, (MAIN WIND FORCE |
| | RESISTING SYSTEM). |
| | 2D) ) FOR ALL ROOF TOP EQUIPMENT, CURBS & FANS DETAILED |
| | ATTACHMENT TO THE ROOF FRAMING & DECK AS WELL AS FROM |
| | THE CURB AND ROOF TOP FAN. 2014 FBC-B 1604.4 ANALYSIS. |
| | LOAD EFFECTS ON STRUCTURAL MEMBERS AND THEIR |
| | CONNECTIONS SHALL BE DETERMINED BY METHODS OF |
| | STRUCTURAL ANALYSIS THAT TAKE INTO ACCOUNT EQUILIBRIUM, |
| | GENERAL STABILITY, GEOMETRIC COMPATIBILITY AND BOTH |
| | SHORT- AND LONG-TERM MATERIAL PROPERTIES. EVERY |
| | STRUCTURE SHALL BE DESIGNED TO RESIST THE OVERTURNING |
| | EFFECTS CAUSED BY THE LATERAL FORCES SPECIFIED IN THIS |
| | CHAPTER. SEE SECTION 1609 FOR WIND LOADS? |
| | |
| | 3) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | CONSTRUCTION SERVICES DIVISION |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |