Plan Review Notes
Plan Review Notes For Permit 16020418
Permit Number 16020418
Review Stop P
Sequence Number 3
Notes
Date Text
2016-05-12 09:55:17THESE PROVISO NOTES ARE ALSO ON THE PLANS.
 **** NOTE**** THE FOLLOWING COMMENTS ARE PROVISOS FOR
 THE PLUMBING PLAN REVIEW ONLY.
 1) THE GAS PERMIT AND PLAN REVIEW WILL BE DONE AS A
 SEPARATE PERMIT AND IS NOT PART OF THIS SUBMITTAL
 PACKAGE.
 2) SHT.IR1.07 - THE ACID INJECTION SYSTEM FOR THE
 IRRIGATION SYSTEM SHALL BE UNDER A SEPARATE PERMIT.
 COMPLETE PLANS AND SPECIFICATIONS SHALL BE SUBMITTED
 FOR REVIEW.
 3) THE LAUNDRY AREAS IN THE CLUBHOUSES SHALL COMPLY
 WITH THE 2014 FBC- ACCESSIBILITY SECS. 611 & 309. ALL
 WASHERS AND DRYERS SHALL COMPLY WITH THE REQUIREMENTS
 FOR CLEAR FLOOR SPACE, OPERABLE PARTS, AND HEIGHT.
 4) SHT.P4.003 - APPROVAL IS REQUIRED FROM THE PALM
 BEACH COUNTY DEPARTMENT OF ENVIRONMENTAL RESOURCE
 MANAGEMENT FOR THE ABOVE GROUND FUEL STORAGE TANKS AND
 DISPENSING SYSTEM PER PALM BEACH COUNTY ORDINANCE
 #2015-008. THE FUEL TANKS AND FUEL DISPENSING SYSTEM
 SHALL BE DONE AS A SEPARATE PERMIT.
 5) THE SANITARY AND WATER RISERS ARE INCOMPLETE AND
 DEFICIENT AND A THOROUGH AND COMPREHENSIVE REVIEW COULD
 NOT BE DONE AT THIS TIME. AS-BUILT SANITARY AND WATER
 RISERS SHALL BE SUBMITTED DURING THE INSPECTION PROCESS
 FOR THESE SYSTEMS.
 6) SHT. A3.23 - ACCESSIBLE ROLL-IN SHOWER WITH GRAB BAR
 AND SEAT DETAIL SH - 3. ALTERNATE ROLL-IN SHOWER
 COMPARTMENTS SHALL COMPLY WITH 2014 FBC-ACCESSIBILITY
 SEC. 608.2.3 FOR ENTRY OPENING AND LAYOUT, SEC.608.3
 FOR THE LOCATION OF GRAB BARS, SEC. 608.5.3 FOR THE
 LOCATION OF CONTROLS, FAUCETS AND SHOWER SPRAY UNITS,
 AND SEC.610.3 FOR SEATS.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  
  
  
  