| 2016-03-10 13:17:16 | PLANNING AND ZONING COMMENTS **UPDATE** |
| | |
| | 3/10/16 |
| | |
| | IN FOLLOW-UP TO COMMENT #7, THE PROPOSED CAPITOL BIKE |
| | RACK WILL NOT BE AN ACCEPTED MODEL FOR USE AS IT LACKS |
| | TWO POINTS OF SUPPORT AND HAS LIMITED ABILITY TO HANDLE |
| | A MIX OF BICYCLE LOCKING MECHANISMS. IF OBLIGATED TO |
| | USE A BICYCLE RACK MODEL PROVIDED BY FORMS + SURFACES, |
| | THE FOLLOWING MODELS WILL BE ACCEPTED - TRIO BIKE RACK, |
| | CORDIA BIKE RACK, SUMMIT BIKE RACK, AND TWIST BIKE |
| | RACK. OTHERWISE, YOU CAN ALSO WORK WITH ANOTHER VENDOR |
| | TO PROVIDE AN ACCEPTABLE MODEL. |
| | |
| | |
| 2016-03-08 17:37:27 | PLANNING AND ZONING COMMENTS: ***FAILED*** |
| | |
| | 3/8/16 |
| | |
| | 1. THERE APPEARS TO BE MORE THAN ONE SITE PLAN |
| | SUBMITTED ? C2.01 AND A1-00 DEPICTING DIFFERENT AMOUNTS |
| | OF INFORMATION. THE SUBMITTED SITE PLAN IS NOT COMPLETE |
| | AND THE FOLLOWING MUST BE ADDRESSED: |
| | A. INCLUDE ALL SITE DATA AND CALCULATIONS. THIS |
| | INFORMATION WILL NEED TO BE UPDATED TO REFLECT ANY |
| | CHANGES TO THE SITE PLAN. |
| | B. BUBBLE ALL CHANGES ON THE SITE PLAN. |
| | C. PROVIDE LABELS FOR ITEMS ON THE PLAN (I.E. COVERED |
| | BATTING TUNNELS, POOL, DUGOUT, ETC.). |
| | D. INCLUDE DIMENSIONS, SETBACKS, ETC. TO DEMONSTRATION |
| | COMPLIANCE OR DEVIATIONS FROM THE APPROVED SITE PLAN. |
| | E. THE HARDSCAPE PLAN SHOWS CHANGES TO FENCE HEIGHTS |
| | AND LOCATIONS WHICH WILL ALSO NEED TO BE UPDATED ON THE |
| | MASTER SITE PLAN. ADDITIONALLY IT IS DIFFICULT TO |
| | LOCATE 4 FOOT FENCE TYPE ON HARDSCAPE PLAN L3.00 THRU |
| | L3.06. |
| | |
| | 2. A MINOR PD AMENDMENT IS REQUIRED FOR ALL CHANGES |
| | FROM THE APPROVED SITE PLAN. THE MINOR PD AMENDMENT |
| | SUBMITTAL NEEDS TO HAVE CALCULATIONS DEMONSTRATING THAT |
| | NONE OF THE MAJOR PD AMENDMENT THRESHOLDS IN RES. |
| | 205-15 ARE EXCEEDED. |
| | |
| | 3. SHEET 7.04 SHOWS THERE IS NO LONGER A 5 FOOT |
| | LANDSCAPE ISLAND NEXT TO THE SOUTHEASTERN MOST PARKING |
| | SPACE BECAUSE THE LIFT STATION APPEARS TO HAVE BEEN |
| | ENLARGED. PLEASE CONFIRM CONFLICTS WITH THE SITE PLAN. |
| | A MINIMUM 5 FOOT LANDSCAPE ISLAND WILL BE REQUIRED. |
| | |
| | 4. SHEET 9.01 - CORRECT STRIPING DETAIL TO PROVIDE 4" |
| | DOUBLE STRIPES, SEPARATED BY 12", AND CONNECTED AT THE |
| | BOTTOM [ZLDR SEC. 94-485, STALL PAINING DETAIL]. SINGLE |
| | STRIPED PARKING SPACES IS NOT PERMITTED. |
| | |
| | 5. SHEET L3.00 - PLEASE NOTE THAT THE COLOR CHOSEN ON |
| | THE HARDSCAPE PLAN TO REPRESENT THE CRUSHED GRAVEL |
| | PATHWAY IS A VERY SIMILAR IN COLOR TO THE PAVED PARKING |
| | AREAS. PLEASE PROVIDE ANOTHER COLOR OR SYMBOL TO |
| | DISTINGUISH THE DIFFERENCE BETWEEN THE CRUSHED GRAVEL |
| | PATHWAY AND PAVED PARKING AREAS. |
| | |
| | 6. SHEET L3.08 - DETAIL 1 FOR STANDARD BIKE RACK DETAIL |
| | - THE BICYCLE RACK SPACING DIMENSIONS ARE FROM THE RACK |
| | ITSELF AND NOT THE CENTER OF THE RACK. PLEASE ACCOUNT |
| | FOR WIDTH OF RACKS IN OVERALL WIDTH OF THE BICYCLE |
| | PARKING PADS TO ENSURE 2.5 FEET CAN BE PROVIDED BETWEEN |
| | RACKS AND 2 FEET FROM THE END RACK TO EDGE OF PAD. |
| | ADJUST SIZES ON SITE PLAN AS NECESSARY. |
| | |
| | 7. SHEET L3.08 - DETAIL 2 FOR CAPITOL BIKE RACK - THIS |
| | MODEL IS UNDER REVIEW AS AN ACCEPTABLE BICYCLE RACK |
| | STYLE FOR USE IN THE CITY. IF APPROVED, PROVIDE A |
| | SPACING DETAIL FOR THE BICYCLE RACKS TO DEMONSTRATE A |
| | MINIMUM 2.5 FEET BETWEEN RACKS, 2 FEET BETWEEN END RACK |
| | AND EDGE OF PAD, AND 6 FEET MINIMUM LENGTH FOR THE |
| | PARKING PAD. |
| | |
| | 8. PLEASE REVIEW ALL PLANS FOR CONSISTENCY WITH BICYCLE |
| | PARKING LOCATIONS. FOR EXAMPLE, PLAZA PARKING IS |
| | DEPICTED DIFFERENTLY IN SHEETS L3.03 AND L4.04. |
| | |
| | 9. ALL EQUIPMENT CORRALS MUST BE SCREENED IN ACCORDANCE |
| | WITH ZLDR SEC. 94-444(B) AND (C). WINDSCREENS ON A |
| | CHAIN-LINK FENCE IS NOT SUFFICIENT. |
| | |
| | 10. SHEET A7.06 - ENTRY LOGO SCULPTURES WILL NEED TO BE |
| | PERMITTED UNDER A SEPARATE PERMIT. PLEASE NOTE THAT |
| | ADDITIONAL REVIEW WILL BE REQUIRED BASED ON THE SIGNAGE |
| | REGULATIONS AND PLACEMENT. THE PROPOSED LOCATION OF |
| | NATIONAL ENTRY LOGO SPANS OVER A SIDEWALK AND 3 OF THE |
| | 6 PROPOSED UPLIGHTS ARE ALSO LOCATED ON THE SIDEWALK. |
| | |
| | 11. SHEET E1-00-3, SHEET E1-00-4 - THERE ARE WALL |
| | MOUNTED JUNCTION BOXES WITHIN THE SETBACK. HOW HIGH ARE |
| | THESE JUNCTION BOXES MOUNTED? |
| | |
| | 12. SEPARATE PERMITS REQUIRED FOR FENCING, LIGHT POLES, |
| | SIGNAGE, LANDSCAPING, AND IRRIGATION. |
| | |
| | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: |
| | |
| | DANIELLE J. KITTREDGE, AICP |
| | SENIOR PLANNER |
| | PLANNING & ZONING DIVISION |
| | PHONE: (561)-822-1443 |
| | EMAIL: [email protected] |
| | |