Plan Review Notes
| Plan Review Notes For Permit 16020417 |
| Permit Number |
16020417 |
|
| Review Stop |
E |
| Sequence Number |
3 |
|
| Notes |
| Date |
Text |
| 2016-04-22 11:08:07 | PLANS ARE FILED UNDER 16020418 | | | | | | 2ND ELECTRICAL REVIEW COMMENTS | | | REVIEWED FOR COMPLIANCE WITH: | | | 5TH EDITION OF THE FBC 2014 & NFPA 70 (NEC) 2011 | | | EDITION | | | | | | WITH THE EXCEPTION OF THE MISSING ILLUMINATION ISSUES, | | | THE BELOW MENTIONED ITEMS CAN BE EASILY ADDRESSED WITH | | | THE PROPER NOTES. THEREFORE A NARRATIVE ADDRESSING THE | | | ISSUES CAN BE ACCEPTED AND PLANS ISSUED WITH A PROVISO | | | RELATING THERETO. | | | | | | AS USUAL, IF DURING THE PLAN REVIEW I MISUNDERSTOOD A | | | SHEET?S INTENTION AND THE COMMENTS ISSUED ARE | | | NON-APPLICABLE PLEASE CORRECT ME AND EXPLAIN. | | | | | | CORRECTIONS REQUIRED: | | | SHEET E1.00-2, E2.111, E3.127, UPLOAD CORRUPTED, | | | SHEET E2.110 | | | 1. PER NEC 680.62 HYDRO TUB OUTLETS SHALL BE GFI | | | PROTECTED. | | | 2. NEC 210.8(B)(7) LOCKER ROOM OUTLETS WITH AN | | | ASSOCIATED SHOWER FACILITY SHALL BE GFCI PROTECTED. | | | SHEET E2.119, E2.112, E2.113, E2.114, E2.117, | | | 1. NEC 210.8(B)(7) LOCKER ROOM OUTLETS WITH AN | | | ASSOCIATED SHOWER FACILITY SHALL BE GFCI PROTECTED. | | | SHEET E2.127 | | | 1. NEC 210.63 REQUIRES A GFCI PROTECTED OUTLET WITH 25? | | | OF EQUIPMENT. AD.0-AE.0/A04.5-A05 | | | SHEET E2.129 | | | 1. EXPLAIN 208/1PH | | | 2. NEC 210.63 REQUIRES A GFCI PROTECTED OUTLET WITH 25? | | | OF EQUIPMENT. OUTLET SHOWN ON PLANS IS OUTSIDE THE | | | ROOM. A08.3-A08.9/AD | | | 3. SAME APPLIES FOR ADJACENT AREA. AD-AB.5/A07.5-A08 | | | SHEET E2.134, E2.132, | | | 1. TYPICAL PADDLE FAN NOTE ADDED TO PLANS. | | | SHEET E2.411, E2.128, E2.126, E2.125, E2.122, | | | 1. EXPLAIN 208/1 PH | | | 2. PANEL SCHEDULE ON SHEET E5.01 DOES NOT INDICATE ANY | | | LOADS ON CKTS 76,9 OF LP-NB-1 | | | SHEET E2.413, E2.412, | | | 1. MISSING THE WEATHER-RESISTANT NOTE ADDED TO ALL | | | OTHER SHEETS. | | | SHEET E3.112, E3.113, E3.114, E3.115, E3.117, E3.118, | | | E3.119, E3.124, E30125, E3.126, E3.128, E3.134, | | | 1. ADDITIONAL EMERGENCY LIGHTING REQUIRED IN ROOMS, | | | 1240, 1235, (SHOWER AND TOILET AREAS OF 1204, 1207), | | | 1211, 1214, 1301, 1310, 1313, 1406, 1413, 1414, 1417, | | | 1419, 1506, 1508, 1512, 1713, 1706, 1708, 1707, 1801, | | | 1831, 1832, 1820, 1901, 1916, 1909, 2428, 2517, 2603, | | | 2607, 2608, 2605, 2616, AREA OF SO5-SO6/SC.5-SB.6, | | | 2811, 2509, | | | 2. LIGHTING CONTROL MISSING IN ROOMS 1205, 1206, 1208, | | | 1321, 1322, 1429, 1417, 1419, 1710, AREA OF | | | SO5-SO6/SC.5-SB.6, 2811, JAN CLOSET BETWEEN 3410 & | | | 3413, 3407, NO3-NO3.5/NC-ND, | | | 3. ILLUMINATION AND CONTROL MISSING IN ROOM 1806, 1907, | | | 1908, 2504, 2508, 2509, CORRIDOR SH-SF/S13.25-S13.5, | | | 3421, | | | | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | | RE-SUBMITTAL, PLEASE PROVIDE A RESPONSE LETTER | | | (NARRATIVE) ADDRESSING EACH ITEM AND THE PAGE NUMBER | | | WHERE THE CORRECTIONS APPEAR ALONG WITH THE STANDARD | | | CITY RE-SUBMITTAL FORM. CLOUDING THE CHANGES WILL BE | | | GREATLY APPRECIATED. | | | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | | CONTACT ME DIRECTLY. | | | | | | THANK YOU, | | | MIKE ALBARRAN | | | ELECTRICAL PLANS EXAMINER | | | PH: 561-805-6746 | | | EMAIL: [email protected] | | | |
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |