| 2016-07-19 10:53:23 | BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 16010427 |
| | ADD: 7150 OKEECHOBEE BLVD. BLDG. TYPE II/ BLDG. # 4. |
| | CONT: ELEV8 CONSTRUCTION CO. / STEVE NAPIER |
| | TEL: 561-891-0414 |
| | E-MAIL: [email protected] |
| | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 3RD REVIEW |
| | DATE: TUES. JULY 19/2016 |
| | ACTION: DENIED |
| | |
| | NOTE: THIS REVIEW IS FOR BUILDING TYPE II, NOT FOR THE |
| | SITE PLAN, OR ANY ASSOCIATED AMENITIES. |
| | |
| | 1) UNDER REVIEW AND CONSIDERATION BY THE BUILDING |
| | OFFICIAL. THE PERMIT APPLICATION VALUE OF $2,800,000.00 |
| | DOLLARS IS LOW. THE AUGUST 2015 ICC VALUATION TABLES |
| | LIST THE VALUE AT: BUILDING TYPE: III B AT |
| | $5,975.852.00 DOLLARS. |
| | NOTE, THE MEP AND ROOFING PERMITS, ARE SUB-PERMITS AND |
| | IF NOT SUBMITTED AT THE TIME OF PERMIT ARE A $80.00 |
| | SUB-PERMIT AND ARE INCLUDED IN THE VALUE OF THE |
| | BUILDING COST. ALL OTHER SUB-PERMITS ARE FEED PERMITS. |
| | PLEASE PROVIDE A LIST OF ALL OTHER SUB-PERMITS FOR THE |
| | BUILDING, SUBMIT A LIST OF PERMITS AND BREAK-OUT THE |
| | VALUE FROM THE TOTAL COST TO DETERMINE THE FINAL |
| | VALUATION OF THE BUILDING PERMIT. |
| | W P B ADMINISTRATIVE CODE 108.2 SCHEDULE OF PERMIT |
| | FEES. ON BUILDINGS, STRUCTURES, ELECTRICAL, GAS, |
| | MECHANICAL AND PLUMBING SYSTEMS OR ALTERATIONS |
| | REQUIRING A PERMIT, A FEE FOR EACH PERMIT SHALL BE PAID |
| | AS REQUIRED, IN ACCORDANCE WITH THE SCHEDULE |
| | ESTABLISHED BY THE APPLICABLE GOVERNING AUTHORITY. |
| | 108.3* BUILDING PERMIT VALUATION. |
| | IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE |
| | CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE, |
| | ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS |
| | APPEARS TO BE UNDER ESTIMATED ON THE APPLICATION, THE |
| | PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES, |
| | VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL |
| | REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND |
| | SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE |
| | STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR |
| | FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR |
| | BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING |
| | COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. |
| | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED |
| | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES |
| | (MARSHALL-SWIFT, MEANS, ETC.) WITH REGIONAL ADJUSTMENTS |
| | FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE |
| | CONGRESS. |
| | |
| | 2) COMPLIED. THRESHOLD BUILDING |
| | |
| | 2F) INFORMATIONAL. NOTE FOR PAPER PLANS 3 SETS OF |
| | DOCUMENTS ARE REQUIRED. FOR DIGITAL PLANS, AFTER PERMIT |
| | ISSUANCE, PLEASE E-MAIL THE PERMIT LIBRARIAN OF THE |
| | PERMIT BEING ISSUED, THE PERMIT LIBRARIAN WILL THEN |
| | E-MAIL YOU THE APPROVED AND BATCH STAMPED PLANS SO YOU |
| | MAY PRINT YOUR PLANS, TWO SETS OF PLANS WILL NEED TO BE |
| | PRINTED IN COLOR, (1) FOR THE THRESHOLD INSPECTOR, THE |
| | OTHER FOR THE MEP INSPECTORS OTHER PLANS YOU WISH TO |
| | PRINT MAYBE IN BLACK & WHITE. |
| | |
| | 2G) NOTICE ONLY, NO ACTION IS REQUIRED. PLEASE CALL THE |
| | CITY OF WEST PALM BEACH?S AUTOMATED TELEPHONE |
| | INSPECTIONS LINE (561) 805-6700) FOR ALL BUILDING |
| | INSPECTIONS FOR AUDITING OF JOBSITE INSPECTIONS WITHOUT |
| | THIS THE PERMIT EXPIRES IN 6 MONTHS, ABANDONMENT OF |
| | JOB, NO INSPECTION ACTIVITY. |
| | |
| | 2H) NOTICE ONLY, NO ACTION IS REQUIRED. 109.3.6 |
| | THRESHOLD BUILDINGS, OPERATING GUIDELINES FOR THRESHOLD |
| | INSPECTORS #26. ASSURE THAT THE DESIGNER HAS REQUIRED |
| | ON THE PLANS OR SPECIFICATIONS ONE MATERIAL, APPROVED |
| | FOR FIRE STOPPING PENETRATIONS, FOR WALLS AND CEILINGS. |
| | |
| | 3-5) COMPLIED |
| | |
| | 6) SEMI-COMPLIED. ENERGY CALCULATIONS WERE SUBMITTED |
| | DIGITALLY. PLEASE NOTE THAT THEY DO NOT HAVE AN |
| | ELECTRONIC SIGNATURE. IF THE DESIGNER DOES NOT SIGN |
| | THEM ELECTRONICALLY, PLEASE SUBMIT AN ORIGINAL SIGNED |
| | AND SEALED SET OF CALCULATIONS, THEY THEN WILL BE FILED |
| | WITH THE OTHER PAPER DOCUMENTS FOR THIS PERMIT. |
| | |
| | 7) BUILDING PROVISO: SHORING & RESHORING PLANS TO BE |
| | SUBMITTED AS A DEFERRED SUBMITTAL, TO BE REVIEWED BY |
| | THE ENGINEER OF RECORD, APPROVED BEFORE SUBMITTAL TO |
| | THE BUILDING DEPARTMENT. |
| | |
| | 8) COMPLIED. |
| | |
| | |
| | 9A-E) ) BUILDING PROVISO: PRODUCT APPROVALS TO BE |
| | DEFERRED SUBMITTALS. |
| | |
| | 9B) DEFERRED SUBMITTALS: COMPONENTS & CLADDING. 2014 |
| | FBC-B 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.4.1 |
| | COMPONENTS & CLADDING. FLORIDA DEPARTMENT OF COMMUNITY |
| | AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF |
| | PRODUCTS OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE |
| | PRODUCT APPROVALS: |
| | (31)(A) EXTERIOR DOORS ,MULLIONS 7 ROOF HATCHES. |
| | (B) WINDOWS & MULLIONS |
| | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL |
| | LOUVERS, EFIS SYSTEMS, |
| | (D) ROOFING PRODUCTS AND ASSEMBLIES, ROOF TOP |
| | VENTILATORS |
| | (E) SHUTTERS |
| | (F) SKYLIGHTS |
| | (G) EXTERIOR COOLER, FREEZERS & PRE-ENGINEERED A/C |
| | STANDS |
| | |
| | 9C) DEFERRED SUBMITTALS: 107.3.4.1 THOSE PRODUCTS WHICH |
| | ARE REGULATED BY DCA RULE 9N-3 SHALL BE REVIEWED AND |
| | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO |
| | SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| | |
| | 9D) DEFERRED SUBMITTALS: FOR ALL PRODUCTS WITH GLAZING, |
| | PLEASE IDENTIFY THE OPENING WIDTH & HEIGHT, TYPE OF |
| | GLAZING, MULLION INFORMATION IF REQUIRED, ATTACHMENTS |
| | AND ASSOCIATE PRESSURES FOR EACH OPENING. |
| | |
| | 9E) DEFERRED SUBMITTALS: FOR ALL ROOFING PRODUCTS |
| | PLEASE IDENTIFY ALL ROOFING SUB-SYSTEMS AND THEIR |
| | ASSOCIATED PRESSURES FOR ROOF ZONE # 1. REVIEW THE |
| | PRODUCT APPROVAL LIMITATIONS, IF ENHANCED FASTENING IS |
| | ALLOWED. IF SO RAS 117 CALCULATIONS ARE REQUIRED BY |
| | EITHER A FLORIDA ARCHITECT OR ENGINEER. |
| | |
| | 9F) COMPLIED. A/C STANDS. , |
| | |
| | 10A) DEFERRED SUBMITTALS. NOTE THIS NOTE APPLIES TO |
| | FLOORS 2-4 ONLY. FBC-B 2014 1207.3 STRUCTURE-BORNE |
| | SOUND. FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS |
| | OR BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA |
| | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION |
| | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD |
| | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. |
| | |
| | 10B) DEFERRED SUBMITTAL. THIS NOTE APPLIES TO WALLS ON |
| | ALL FLOORS. WALL TYPES FOUND ON SHEET A8.01, THE WALL |
| | TYPES DO NOT PROVIDE THE REQUIRED STC RATING NOR TEST |
| | RESULTS IN ACCORDANCE WITH: FBC-B 2014 1207.2 AIR-BORNE |
| | SOUND. WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES |
| | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM |
| | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION |
| | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) |
| | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM |
| | E 90. |
| | |
| | 10C) DEFERRED SUBMITTAL. NOTE THIS IS A VERY |
| | RESTRICTIVE REQUIREMENT!!! |
| | TYPE III-TYPE V CONSTRUCTION: FBC-B-2014 720.2 |
| | CONCEALED INSTALLATION. |
| | INSULATING MATERIALS, WHERE CONCEALED AS INSTALLED IN |
| | BUILDINGS OF ANY TYPE OF CONSTRUCTION, SHALL HAVE A |
| | FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A |
| | SMOKE-DEVELOPED INDEX OF NOT MORE THAN 450. |
| | FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS |
| | A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL |
| | MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A |
| | MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. |
| | |
| | 11) 1ST FLOOR/ SHEET A2.02.II, |
| | |
| | 11A-D COMPLIED. |
| | |
| | 11E) PROVISO: THE GARAGES ALL SHOW ON SHEET E1.01 & |
| | E5.01 CIRCUITRY TO INCLUDE A GARAGE DOOR OPENER. PLEASE |
| | PROVIDE COMPLIANCE WITH THE 2014 FBC-B 406.3.5 |
| | AUTOMATIC GARAGE DOOR OPENERS. AUTOMATIC GARAGE DOOR |
| | OPENERS, IF PROVIDED, SHALL BE LISTED IN ACCORDANCE |
| | WITH UL 325. IF THERE IS A POWER FAILURE OR A |
| | MECHANICAL BREAKDOWN WITHOUT ANY OTHER MEANS OF EGRESS |
| | HOW WILL ENTRY INTO A GARAGE BE ACHIEVED. 107.2.1.3. |
| | ADDITIONAL INFORMATION IS REQUIRED. |
| | |
| | 11F-L)COMPLIED. |
| | |
| | 12-14) COMPLIED. |
| | |
| | 15) PROVISO: SHEET A8.02 DETAIL # 11 SHOWS A SLIDING |
| | GLASS DOOR. THE HEIGHT OF THE SLIDING GLASS DOOR SILL |
| | WILL BE DETERMINED BY THE SLIDING GLASS DOOR PRODUCT |
| | APPROVAL AND ASSOCIATED PRESSURES. SHEET A8.02 . |
| | |
| | 16-18) COMPLIED. |
| | |
| | 19) COMPLIED. |
| | |
| | 20) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT |
| | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL |
| | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND |
| | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT |
| | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | 21) WHEN RESUBMITTING PLANS PLEASE INDICATE THE |
| | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES |
| | AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |