| Date |
Text |
| 2016-01-23 09:00:12 | BUILDING PLAN REVIEW |
| | W. P. B. REVISION: 16010356 REV. # 15 |
| | W. P. B. PERMIT: 14050111 |
| | ADD: 600 OKEECHOBEE BLVD. |
| | CONT: COASTAL |
| | TEL: 561-659-5819 |
| | E-MAIL: |
| | |
| | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| | FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: SAT. JAN. 23/2016 |
| | ACTION: DENIED |
| | |
| | 1) REVISION # 15 DENIED INTHE NORTHWEST CORNER OF THE |
| | PROPERTY AFTER THE LAST SET OF 3 GATES THE OCCUPANT |
| | LOAD IS STATED AS 600 OCCUPANTS, WITH THE OCCUPANT LOAD |
| | EXITING THE VERTICAL STAIR OF 150 OCCUPANTS ADDED TO |
| | THE EXIT DISCHARGE A NEW TOTAL OF 750 OCCUPANTS WHERE |
| | AS THE PLANS INDICATE THE EGRESS WIDTH OF 120 INCHES |
| | GOOD FOR 120 OCCUPANTS, 120/.2= 600 OCCUPANTS. 1027.2 |
| | EXIT DISCHARGE CAPACITY. THE CAPACITY OF THE EXIT |
| | DISCHARGE SHALL BE NOT LESS THAN THE REQUIRED DISCHARGE |
| | CAPACITY OF THE EXITS BEING SERVED. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | DEVELOPMENT SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| | |
| | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| | |
| | |
| | |