| 2016-05-16 16:10:15 | BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 16010290 |
| | ADD: 805 N. RAILROAD AVE. |
| | CONT: PALM BEACH CAST STONE |
| | TEL: 561-835-4085 |
| | E-MAIL: [email protected] |
| | |
| | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| | FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 3RD REVIEW |
| | DATE: MON. MAY 16/2016 |
| | |
| | ****PRIVATE PROVIDER**** |
| | ACTION: BUILDING PROVISO: |
| | |
| | 1) BUILDING APPROVED WITH EXCEPTION! |
| | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO |
| | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO |
| | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE |
| | ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE |
| | ADDITIONAL REVIEWS WITH ASSOCIATED FEES. |
| | THE SUBMITTED CARRIER CUBE UNIT IS A GENERIC ANALYSIS |
| | WITH MANY VARIABLES. PLEASE SUPPLY A SITE SPECIFIC |
| | ANALYSIS, WITH SIGNED AND SEALED DOCUMENTS. THE |
| | DOCUMENTS SUBMITTED ARE COPIES, ALSO THEY DO NOT HAVE A |
| | INDEX INDICATING HOW MANY SHEETS ARE WITHIN THE REPORT. |
| | PLEASE PROVIDE COMPLIANCE WITH : |
| | FLORIDA ADMINISTRATIVE CODE 61G15-23.002(2) FL. ADMIN. |
| | CODE. A COVER SHEET OR INDEX SHEET FOR ENGINEERING |
| | SPECIFICATIONS MAY BE USED AND THAT SHEET MUST BE |
| | SIGNED IN RESPONSIBLE CHARGE OF THE PRODUCTION & |
| | PREPARATION OF EACH SECTION OF THE ENGINEERING |
| | SPECIFICATION WITH SUFFICIENT INFORMATION ON THE COVER |
| | SHEET OR INDEX LISTING HOW MANY PAGES ARE COVERED UNDER |
| | THE COVER SHEET OR INDEX SHEET. . |
| | |
| | 2) BUILDING PROVISO: 2014 FLORIDA BUILDING CODE W 2014 |
| | WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING |
| | CODE, CHAPTER 1, ADMINISTRATION, 106.1 LIVE LOADS |
| | POSTED. WHERE THE LIVE LOADS FOR WHICH EACH FLOOR OR |
| | PORTION THEREOF OF A COMMERCIAL OR INDUSTRIAL BUILDING |
| | IS OR HAS BEEN DESIGNED TO EXCEED 50 PSF (2.40 KN/M2), |
| | SUCH DESIGN LIVE LOADS SHALL BE CONSPICUOUSLY POSTED BY |
| | THE OWNER IN THAT PART OF EACH STORY IN WHICH THEY |
| | APPLY, USING DURABLE SIGNS. IT SHALL BE UNLAWFUL TO |
| | REMOVE OR DEFACE SUCH NOTICES. |
| | |
| | 3) BUILDING PROVISO: 2014 FLORIDA BUILDING CODE W 2014 |
| | WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING |
| | CODE, CHAPTER 1, ADMINISTRATION, 106.2 ISSUANCE OF |
| | CERTIFICATE OF OCCUPANCY. A CERTIFICATE OF OCCUPANCY |
| | REQUIRED BY SECTION 111 SHALL NOT BE ISSUED UNTIL THE |
| | FLOOR LOAD SIGNS, REQUIRED BY SECTION 106.1, HAVE BEEN |
| | INSTALLED. |
| | |