| 2016-02-25 10:07:23 | BUILDING PLAN REVIEW |
| | W. P. B. REVISION: 16010266 |
| | W. P. B. PERMIT: 15080631 |
| | ADD: 7320 S. DIXIE HWY |
| | CONT: CAL DEVELOPMENT |
| | TEL: (954)564-0655 |
| | E-MAIL: [email protected] |
| | |
| | 2014 FLORIDA BUILDING CODE W |
| | * 2014WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, |
| | |
| | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| | FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 2ND REVIEW |
| | DATE: THURS. FEB. 25/ 2016 |
| | ACTION: DENIED |
| | |
| | NOTICE!!!!!!!!!!!!! CHAPTER 553.80(2)(B) FLORIDA |
| | STATUTES STATES THAT A LOCAL GOVERNMENT SHALL IMPOSE A |
| | FEE OF FOUR TIMES THE FEE FOR PLAN REVIEW, IF PLANS ARE |
| | REJECTED (3) OR MORE TIMES FOR REPEATED FAILURE TO |
| | CORRECT A CODE VIOLATION. |
| | |
| | 1) SUBMITTALS AND REVISIONS SUBMITTED: HAVE A NPJ |
| | TECHNICAL SERVICES ON THE TOP OF ALL THE SUBMITTALS, |
| | PLEASE IDENTIFY WHAT YOUR RELATIONSHIP IS WITH THIS |
| | PROJECT. YOU ARE NOT THE ARCHITECT OF RECORD (DANA |
| | MULLER AR 92911) NOR THE MECHANICAL ENGINEER NISIT |
| | SAPPARKHAO NOR THE CONTRACTOR CAL DEVELOPMENT. |
| | ALL SUBMITTALS ARETO BE REVIEWED BY THE DESIGNER OF |
| | RECORD (ARCHITECT) FL 61G1-23.015 (2) THE ARCHITECT IS |
| | RESPONSIBLE FOR SUPERVISING AND REVIEWING ALL PROJECT |
| | DATA, REPORTS, SHOP DRAWINGS ETC... |
| | |
| | THE SECOND ISSUE IS THE SUBMITTAL ONLY LIST ALUMINUM |
| | HANDRAIL MODIFICATIONS WITHIN THIS PACKAGE THERE IS: |
| | A) STAIR TREAD MODIFICATION AS WELL AS HANDRAIL |
| | MODIFICATIONS THOMAS J. TWOMEY P.E. |
| | B) EXTERIOR LOUVERS NOA10-0920.16 SIZED TO LESS THAN ? |
| | OF THE 8X11 SHEET. NOT READABLE FOR RECORD RETENTION. |
| | C) CEILING AND WALL A/C GRILLS |
| | D) FIRE DAMPERS |
| | E) DC-CSSF-NN WELDED ROOF CURB |
| | F) NOA 14-1224.14 GAF MASTER FLOW GALVANIZED WIND |
| | TURBINE |
| | |
| | 1A) 2ND REQUEST. ROOF CURBS : MODEL DC-CSSF-NN |
| | MANUFACTURERS CUT SHEET INDICATES THEY HAVE MIAMI-DADE |
| | NOA'S, LISTED ON CUT SHEET. THERE IS NO ENGINEERS |
| | SIGNATURE AND SEAL ASSOCIATED WITH THIS SHEET ALTHOUGH |
| | THERE ARE TIE DOWN DIRECTIONS FOR VARIOUS TYPES OF ROOF |
| | DECKS, NOR IS THERE A WIND DESIGN CRITERIA INDICATING |
| | TO WHAT WIND DESIGN THIS WAS TESTED. ALSO PROVIDE THE |
| | MEAN ROOF HEIGHT OF THE BUILDING, NOTE THIS IS A 3 |
| | STORY BUILDING WITH WOOD FLOOR AND ROOF TRUSSES WITH A |
| | DRIVE THRU ON THE 1ST FLOOR. |
| | |
| | PLEASE PROVIDE COMPLIANCE WITH: 2014 FBC-B 1609.1.2 |
| | PROTECTION OF OPENINGS, 1609.6.4.4.1 COMPONENTS & |
| | CLADDING. FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE |
| | 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR |
| | CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT |
| | APPROVALS: |
| | (31)D) ROOFING PRODUCTS AND ASSEMBLIES, ROOF TOP CURBS |
| | |
| | 1B) 2ND REQUEST. 107.3.4.1 THOSE PRODUCTS WHICH ARE |
| | REGULATED BY DCA RULE 9N-3 SHALL BE REVIEWED AND |
| | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO |
| | SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. |
| | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION |
| | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: |
| | (31)(A) EXTERIOR DOORS. |
| | (B) WINDOWS |
| | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL |
| | LOUVERS, EFIS SYSTEMS, |
| | (D) ROOFING PRODUCTS AND ASSEMBLIES, ROOF TOP CURBS, |
| | INTAKE AND OR EXHAUST FANS |
| | (E) SHUTTERS |
| | (F) SKYLIGHTS |
| | (G) EXTERIOR COOLER, FREEZERS & PRE-ENGINEERED A/C |
| | STANDS |
| | |
| | 1C) 2ND REQUEST. THE MECHANICAL SHEET M01.01 DOES SHOW |
| | THE USE OF THE 12 INCH GALVANIZED WIND TURBINE |
| | INSTALLED ON A ROOF TOP STAND. THIS SAME DETAIL SHOWS |
| | THE TURBINE WITH A LIPPED VERTICAL EDGE TO ATTACH THE |
| | TURBINE TO THE BASE. NOTE THE TURBINE DOES NOT COME |
| | WITH THIS LIPPED EDGE, LIMITATION NOTE 3 THIS TURBINE |
| | IS TO BE USED ON SLOPED ROOFS, WITH WOOD DECKS. |
| | THE OTHER ISSUE IS IN LIMITATION # 4 ONLY ALLOWS THE |
| | USE OF HIS PRODUCT TO 33 FEET ABOVE GRADE!!!!!!!! |
| | |
| | THE NOA SUBMITTED 14-1224.14 GAF MASTER FLOW 12 INCH |
| | GALVANIZED WIND TURBINE, PLEASE REVIEW PAGE 4 OF 5, |
| | UNDER THE HEADING OF LIMITATIONS: NOTE # 3. THIS |
| | ACCEPTANCE IS FOR INSTALLATION WITH ASPHALT SHINGLE |
| | ROOF SYSTEMS ONLY. NOTE # 4 LIMITATION, VENT NOT TO BE |
| | INSTALLED ON ROOF MEAN HEIGHT GREATER THAN 33 FEET. |
| | |
| | 1D) 2ND REQUEST. ALUMINUM HANDRAIL/ GUARDRAIL SYSTEM |
| | SUBMITTAL, SEE SHEET A00.30 DETAIL #4 NOTE # 1. |
| | CONTRACTOR TO PROVIDE SIGNED AND SEALED SHOP DRAWINGS |
| | AND CALCULATIONS OF THE GUARDRAIL DESIGN TO THE |
| | ARCHITECT. |
| | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR |
| | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, |
| | SHOP DRAWINGS ETC... |
| | |
| | 1E) WHEN RESUBMITTING PLANS PLEASE INDICATE THE |
| | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES |
| | AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |