| Date |
Text |
| 2015-12-17 16:21:14 | RESIDENTIAL (R3) RE-ROOF, BUILDING REVIEW COMMENTS. |
| | CODE: FBC-RESIDENTIAL 5TH EDITION (2014). |
| | |
| | 1- FLAT ROOF NOA 14-0224.03 SUBMITTED: |
| | (A) CLEARLY IDENTIFY APPROVED ASSEMBLY TO BE INSTALLED |
| | TO VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF SEC. |
| | R301 OF FBC-RESIDENTIAL, 5TH EDITION (2014). |
| | |
| | (B) PROVIDE SIGNED AND SEALED RAS 117 AS REQUIRED BY |
| | GENERAL LIMITATION #7 ON LAST PAGE OF NOA SUBMITTED. |
| | NOTE: SELECTED ASSEMBLIES THAT HAVE GENERAL LIMITATION |
| | #9 CAN NOT BE USED BECAUSE THEY DON'T ALLOW ENGINEER |
| | CALCULATIONS. SEE GENERAL LIMITATION #9 ON LAST PAGE OF |
| | NOA SUBMITTED. NEED THE CALCULATIONS TO MEET THE DESIGN |
| | PRESSURES OF SEC. R301 OF FBC-RESIDENTIAL, 5TH EDITION |
| | (2014). |
| | |
| | 2- CONCRETE TILE NOA 14-1120.08 SUBMITTED: CLEARLY |
| | IDENTIFY HOW IS THE TILE GOING TO BE FASTENED. |
| | (A) IF IT'S NAILS OR SCREWS, THEN SPECIFY NAIL OR SCREW |
| | TYPE AND NUMBER REQUIRED. PROVIDE CALCULATIONS SHOWING |
| | THE CALCULATED MOMENT OF RESISTANCE (SEE PAGE 4 OF 6 OF |
| | NOA SUBMITTED) TO VERIFY THAT TYPE AND NUMBER OF |
| | NAILS/SCREWS WILL WORK. |
| | |
| | (B) IF USING ADHESIVE, THEN PROVIDE PRODUCT APPROVAL (2 |
| | COPIES) AS REQUIRED BY FAC 61G20-3.002(33). NOTE: SEE |
| | NOA SUBMITTED FOR LISTED ADHESIVES. |
| | |
| | 3- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO |
| | LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS AND |
| | CONTRACTOR'S OVERHEAD AND PROFIT AS REQUIRED BY SEC. |
| | 109.3 CITY AMENDMENTS. THE VALUATION WAS UPDATED TO |
| | $50,070. THE PERMIT FEE BALANCE IS $1135.20. |
| | |
| | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | (561)805-6712 |