| 2016-01-12 12:25:28 | 1ST REVIEW: FBC 2014 5TH ED. RESIDENTIAL |
| | |
| | PLANS INDICATE NEW ROOFING AND WINDOWS. DISCUSSION WITH |
| | CONTRACTOR INDICATES ROOFING IS BY EXISTING PERMIT |
| | 15110990 AND WINDOWS WILL BE BY SEPARATE PERMIT UNDER |
| | SEPARATE CONTRACT AND ACCORDINGLY NOT PART OF THE SCOPE |
| | OF THIS PERMIT. PLEASE VERIFY AND MODIFY THE PLAN TO SO |
| | INDICATE. OTHERWISE, PROVIDE PRODUCT APPROVALS REVIEWED |
| | BY THE DESIGNER OF RECORD. |
| | |
| | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE |
| | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED |
| | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. |
| | |
| | PROVIDE STRUCTURAL AND WALL FINISH DETAILS FOR THE NEW |
| | INFILL WALL AT OUTDOOR SHOWER AREA ON SHEET A100.1. |
| | PROVIDE STRUCTURAL AND BUCK DETAILS FOR NEW WINDOW |
| | OPENINGS AND AS INDICATED ABOVE CLARIFY WHOM SHALL BE |
| | RESPONSIBLE FOR WINDOW PRODUCTS. |
| | |
| | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
| | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY |
| | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK |
| | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE |
| | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, |
| | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING |
| | OFFICIAL. |
| | |
| | INDICATE SMOKE/CARBON MONOXIDE INFORMATION. |
| | |
| | FBC- 107.3.5.3 ? PROVIDE SMOKE DETECTORS PURSUANT TO |
| | FBC-R 314.3.1 AS REQUIRED FOR NEW DWELLINGS. |
| | |
| | FBC-R 315.1 ? PROVIDE CARBON MONOXIDE ALARMS WITHIN 10 |
| | FEET OF EACH SLEEPING ROOM. |
| | |
| | STEVEN KENNEDY, CBO |
| | CHIEF PLANS EXAMINER |
| | (561) 805-6710 |
| | [email protected] |
| | |