2016-04-12 13:55:50PLUMBING COMMENTS:
  
 1. SHT A-5 SHOW COMPLIANCE WITH FBC ACC.SEC. 609.4
 POSITION OF GRAB BARS.
 GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL POSITION,
 33 INCHES (840 MM) MINIMUM AND 36 INCHES (915 MM)
 MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF
 THE GRIPPING SURFACE,
  
 2. SHT. A-5 SHOW THE LAVS IN COMPLIANCE WITH FBC
 ACC.SEC 306.3 KNEE AND TOE CLEARANCE.
  
 3.SIZE ALL PIPING ON GREASE,SANITARY AND WATER RISER
 DIAGRAMS. PER WPB AMEND. TO FBC 107.2.1
  
 4. THE FLOOR DRAINS IN BATHROOMS SHALL CONNECT TO WET
 VENT INDIVIDUALLY. PER FBC PLSEC. 912.1
  