| Date |
Text |
| 2016-01-22 13:31:36 | |
| | 2ND REVIEW: FBC 2014 |
| | |
| | GEORGE JOHNSON |
| | PLUMBING PLANS EXAMINER |
| | CITY OF WEST PALM BEACH |
| | 561-805-6711 |
| | [email protected] |
| | |
| | PLUMBING COMMENTS: |
| | |
| | 1. A GREASE TRAP FOR 3 COMP SINK WILL BE REQUIRED TO |
| | COMPPLY WITH FBC EXIST. |
| | SECSECTION 810 PLUMBING |
| | |
| | 810.1 MINIMUM FIXTURES. |
| | WHERE THE OCCUPANT LOAD OF THE STORY IS INCREASED BY |
| | MORE THAN 20 PERCENT, PLUMBING FIXTURES FOR THE STORY |
| | SHALL BE PROVIDED IN QUANTITIES SPECIFIED IN THE |
| | FLORIDA BUILDING CODE, PLUMBING BASED ON THE INCREASED |
| | OCCUPANT LOAD. |
| | FBC PLUMB. SECTION 1003 INTERCEPTORS AND SEPARATORS |
| | |
| | 1003.1 WHERE REQUIRED. |
| | INTERCEPTORS AND SEPARATORS SHALL BE PROVIDED TO |
| | PREVENT THE DISCHARGE OF OIL, GREASE, SAND AND OTHER |
| | SUBSTANCES HARMFUL OR HAZARDOUS TO THE PUBLIC SEWER, |
| | THE PRIVATE SEWAGE SYSTEM OR THE SEWAGE TREATMENT PLANT |
| | OR PROCESSES |
| | 1003.3.1 GREASE INTERCEPTORS AND AUTOMATIC GREASE |
| | REMOVAL DEVICES REQUIRED. |
| | A GREASE INTERCEPTOR OR AUTOMATIC GREASE REMOVAL DEVICE |
| | SHALL BE REQUIRED TO RECEIVE THE DRAINAGE FROM FIXTURES |
| | AND EQUIPMENT WITH GREASE-LADEN WASTE LOCATED IN FOOD |
| | PREPARATION AREAS, SUCH AS IN RESTAURANTS, HOTEL |
| | KITCHENS, HOSPITALS, SCHOOL KITCHENS, BARS, FACTORY |
| | CAFETERIAS AND CLUBS. FIXTURES AND EQUIPMENT SHALL |
| | INCLUDE POT SINKS, PRERINSE SINKS; SOUP KETTLES OR |
| | SIMILAR DEVICES; WOK STATIONS; FLOOR DRAINS OR SINKS |
| | INTO WHICH KETTLES ARE DRAINED; AUTOMATIC HOOD WASH |
| | UNITS AND DISHWASHERS WITHOUT PRERINSE SINKS. GREASE |
| | INTERCEPTORS AND AUTOMATIC GREASE REMOVAL DEVICES SHALL |
| | RECEIVE WASTE ONLY FROM FIXTURES AND EQUIPMENT THAT |
| | ALLOW FATS, OILS OR GREASE TO BE DISCHARGED. WHERE LACK |
| | OF SPACE OR OTHER CONSTRAINTS PREVENT THE INSTALLATION |
| | OR REPLACEMENT OF A GREASE INTERCEPTOR, ONE OR MORE |
| | GREASE INTERCEPTORS SHALL BE PERMITTED TO BE INSTALLED |
| | ON OR ABOVE THE FLOOR AND UPSTREAM OF AN EXISTING |
| | GREASE INTERCEPTOR |