Plan Review Notes
Plan Review Notes For Permit 15120184
Permit Number 15120184
Review Stop P
Sequence Number 1
Notes
Date Text
2015-12-10 13:33:511ST REVIEW: FBC 2014
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  
 PLUMBING COMMENTS:
  
 1. THE FIXTURE DRAIN FOR WASHING MACHINE MUST TIE INTO
 BUILDING DRAIN DOWNSTREAM OF THE BATHROOM GROUP. PER
 FBC P SEC 912.1
 SHEET P-1 REFERS TO PLUMBING CODE AS FBC 2901 IT SHALL
 BE FBC 2014.
 3. P-1 AND E-1 DO NOT COMPLY WITH FAC SEC 61G15-23.003
 PROCEDURES FOR PHYSICALLY SIGNING AND SEALING PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.
 ENGINEERING PLANS, SPECIFICATIONS, REPORTS OR OTHER
 DOCUMENTS WHICH MUST BE SIGNED, DATED AND SEALED IN
 ACCORDANCE WITH THE PROVISIONS OF SECTION 471.025,
 F.S., AND RULE 61G15-23.001, F.A.C. MAY BE PHYSICALLY
 SIGNED, DATED AND SEALED AS PROVIDED HEREIN BY THE
 PROFESSIONAL ENGINEER IN RESPONSIBLE CHARGE.
 (1) THE LICENSEE SHALL SIGN BY HAND AN ORIGINAL OF THE
 LICENSEE?S SIGNATURE ON EACH PAGE REQUIRED TO BE
 SEALED. A SCANNED, FACSIMILE, DIGITALLY CREATED OR
 COPIED IMAGE OF THE LICENSEE?S SIGNATURE SHALL NOT BE
 USED.
 (2) THE LICENSEE MUST THEN USE A WET SEAL, A DIGITALLY
 CREATED SEAL, OR AN EMBOSSING SEAL PLACED PARTIALLY
 OVERLAPPING THE LICENSEE?S SIGNATURE ON EACH PAGE
 REQUIRED TO BE SEALED. THE PLACEMENT OF THE SEAL SHALL
 NOT RENDER THE SIGNATURE ILLEGIBLE
 4. APPLICATION REFERENCES SWIMMING POOL BUT ITS NOT ON
 THE PRINT PLEASE CLARIFY. PER WPB AMEND. TO FBC SEC
 107.2.1
  