| Plan Review Notes For Permit 15111061 |
| Permit Number |
15111061 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2015-11-30 16:01:34 | RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS. | | | CODE: FBC-5TH EDITION (2014). | | | | | | 1- FLAT ROOF NOA 13-1217.01 SUBMITTED: SELECTED | | | ASSEMBLY ON PAGE 26 IS GOOD FOR A MAXIMUM DESIGN | | | PRESSURE OF -52.5PSF. NEED TO PROVIDE SIGNED AND SEALED | | | RAS 117 CALCULATIONS AS REQUIRED BY GENERAL LIMITATION | | | #7 ON LAST PAGE OF NOA 13-1217.01 SUBMITTED. NEED | | | CALCULATIONS TO MEET THE DESIGN PRESSURES REQUIRED BY | | | SEC. R301 OF FBC-RESIDENTIAL, 5TH EDITION (2014). | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] |
|