Plan Review Notes
Plan Review Notes For Permit 15111020
Permit Number 15111020
Review Stop Z
Sequence Number 2
Notes
Date Text
2016-08-23 16:20:18ZONING PLAN REVIEW
 ___________________________________________
  
 DATE OF REVIEW: 8.23.2016
 PERMIT NO.: 15111020
 ADDRESS: 1100 SOUTH FLAGLER DRIVE
 CONTRACTOR/CONTACT: DAN PETROVIC
 TELEPHONE NO.: 305.590.5000
 SCOPE OF REVIEW: NEW CONDOMINIUM BUILDING.
 ___________________________________________
  
 REVIEW STATUS: FAILED
 ___________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. THE FOLLOWING ITEMS ARE OF CONCERN AND DO NOT MATCH
 THAT WHICH WAS APPROVED THROUGH THE MINOR PD AMENDMENT
 ISSUED ON SEPTEMBER 9, 2015:
  
  A. REGARDING THE PARKING LAYOUT FOR P-2, AS SHOWN ON
 SHEET A0.31 AND A2.0P2:
  
  I. A PARKING TURN-AROUND NEEDS TO BE PROVIDED IN THE
 NORTHWEST CORNER OF THE GARAGE AS THIS IS A DEAD-END.
  
  II. STRUCTURAL COLUMNS APPEAR TO ENCROACH INTO
 SEVERAL PARKING SPACES.
  
  B. REGARDING THE PARKING LAYOUT FOR P-1, AS SHOWN ON
 SHEET A0.31 AND A2.0P1:
  
  I. A PARKING TURN-AROUND NEEDS TO BE PROVIDED IN THE
 NORTHEAST CORNER OF THE GARAGE AS THIS IS A DEAD-END.
  
  II. STRUCTURAL COLUMNS APPEAR TO ENCROACH INTO
 SEVERAL PARKING SPACES.
  
 2. PARKING STRIPING DETAIL SHALL BE PROVIDED.
  
 3. IT IS STAFF'S UNDERSTANDING THAT THE FIRE LANE ON
 THE SOUTH, EAST, AND NORTH SIDES OF THE BUILDING IS NO
 LONGER REQUIRED. IT IS STRONGLY ENCOURAGED THAT THIS
 AREA BE LOOKED AT FOR ADDITIONAL LANDSCAPING AND DESIGN
 ELEMENTS THAT MAY NOW BE INSTALLED.
  
 4. PLEASE PROVIDE THE OUTLINE OF THE TOWER ON THE SITE
 PLAN, ENSURING COMPLIANCE WITH THE APPROVED SETBACK.
  
 5. FURTHER EXPLANATION AND DISCUSSION NEEDS TO BE HAD
 REGARDING GUEST SUITES. ACCORDING TO THE PLANS IT
 APPEARS THAT 12 GUEST SUITES ARE PROPOSED.
  
 6. PHOTOMETRIC PLANS SHALL BE PROVIDED FOR ALL EXTERIOR
 LIGHTING, AND LEVELS SHALL NOT EXCEED 0.5 FOOTCANDLES
 WHEN MEASURED AT THE PROPERTY LINE.
  
 THE FOLLOWING COMMENTS ARE NOT REQUIRED TO BE ADDRESSED
 PRIOR TO ISSUANCE OF THE BUILDING PERMIT, AND DO NOT
 REQUIRE MODIFICATIONS TO THE BUILDING PLANS AS PART OF
 THIS SUBMITTAL, BUT SHOULD BE CONSIDERED AS PROVISOS:
  
 1. ALL LANDSCAPE PLANS SHALL BE SUBMITTED AND REVIEWED
 UNDER A SEPARATE LANDSCAPE PERMIT APPLICATION.
  
 2. THE PROPOSED PLANTING WITHIN THE CITY'S RIGHT-OF-WAY
 SHALL BE SUBJECT TO THE REVIEW AND APPROVAL BY THE
 CITY'S ENGINEERING SERVICES DEPARTMENT.
  
 3. PRIOR TO THE ISSUANCE OF THE LANDSCAPE PERMIT, THE
 APPLICANT SHALL SUBMIT THE MOST RECENT APPROVED
 LANDSCAPE PLANS AND TREE MITIGATION CHART AS A REVISION
 TO THE TREE ALTERATION PERMIT.
  
 4. PRIOR TO APPROVAL OF THE FINAL LANDSCAPE INSPECTION,
 LANDSCAPE MATERIAL SHALL BE PROVIDED AROUND THE
 UTILITIES (BACKFLOW PREVENTERS, DOUBLE CHECK DETECTORS,
 ETC.) AT THE SOUTH END OF THE PROPERTY, ALONG SOUTH
 FLAGLER DRIVE, TO MINIMIZE THEIR VISUAL IMPACT. SUCH
 MATERIAL MAY CONSIST OF SHRUBS AND/OR GROUNDCOVER USED
 TO DISGUISE THE UTILITIES. ADDITIONALLY, THE UTILITIES
 SHALL BE PAINTED IN A COLOR THAT MINIMIZES THEIR
 VISIBILITY.
  
 5. A MINOR PD AMENDMENT SHALL BE SUBMITTED TO THE
 DEVELOPMENT SERVICES DEPARTMENT - PLANNING DIVISION TO
 UPDATE ALL PLANS PREVIOUSLY-APPROVED AS PART OF THE
 RESIDENTIAL PLANNED DEVELOPMENT (RPD), REFLECTING ALL
 REVISIONS THAT HAVE OCCURRED TO DATE.
 ___________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ___________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN P. ROACH, AICP, PRINCIPAL PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1448
 F: 561.822.1460
  
 E: [email protected]
  
 W: WPB.ORG
  