2016-01-12 10:42:52APPROVED WITH EXCEPTION; COMPLY WITH THE BELOW:
  
 R4501.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENT.
 RESIDENTIAL SWIMMING POOLS SHALL COMPLY WITH SECTIONS
 R4501.17.1 THROUGH R4501.17.3.
  
 EXCEPTION: A SWIMMING POOL WITH AN APPROVED SAFETY POOL
 COVER COMPLYING WITH ASTM F 1346.
  
 R4502.17.1 OUTDOOR SWIMMING POOLS.
 OUTDOOR SWIMMING POOLS SHALL BE PROVIDED WITH A BARRIER
 COMPLYING WITH SECTIONS R4501.17.1.1 THROUGH
 R4501.17.1.14.
  
 R4501.17.1.1
 THE TOP OF THE BARRIER SHALL BE AT LEAST 48 INCHES
 (1219 MM) ABOVE GRADE, MEASURED ON THE SIDE OF THE
 BARRIER WHICH FACES AWAY FROM THE SWIMMING POOL. THE
 MAXIMUM VERTICAL CLEARANCE BETWEEN GRADE AND THE BOTTOM
 OF THE BARRIER SHALL BE 2 INCHES (51 MM) MEASURED ON
 THE SIDE OF THE BARRIER WHICH FACES AWAY FROM THE
 SWIMMING POOL. WHERE THE TOP OF THE POOL STRUCTURE IS
 ABOVE GRADE, THE BARRIER MAY BE AT GROUND LEVEL OR
 MOUNTED ON TOP OF THE POOL STRUCTURE. WHERE THE BARRIER
 IS MOUNTED ON TOP OF THE POOL STRUCTURE, THE MAXIMUM
 VERTICAL CLEARANCE BETWEEN THE TOP OF THE POOL
 STRUCTURE AND THE BOTTOM OF THE BARRIER SHALL BE 4
 INCHES (102 MM).
  
 R4501.17.1.2
 THE BARRIER MAY NOT HAVE ANY GAPS, OPENINGS,
 INDENTATIONS, PROTRUSIONS, OR STRUCTURAL COMPONENTS
 THAT COULD ALLOW A YOUNG CHILD TO CRAWL UNDER, SQUEEZE
 THROUGH, OR CLIMB OVER THE BARRIER AS HEREIN DESCRIBED
 BELOW. ONE END OF A REMOVABLE CHILD BARRIER SHALL NOT
 BE REMOVABLE WITHOUT THE AID OF TOOLS. OPENINGS IN ANY
 BARRIER SHALL NOT ALLOW PASSAGE OF A 4-INCH-DIAMETER
 (102 MM) SPHERE.
  
 R4501.17.1.3
 SOLID BARRIERS WHICH DO NOT HAVE OPENINGS SHALL NOT
 CONTAIN INDENTATIONS OR PROTRUSIONS EXCEPT FOR NORMAL
 CONSTRUCTION TOLERANCES AND TOOLED MASONRY JOINTS.
  
 R4501.17.1.4
 WHERE THE BARRIER IS COMPOSED OF HORIZONTAL AND
 VERTICAL MEMBERS AND THE DISTANCE BETWEEN THE TOPS OF
 THE HORIZONTAL MEMBERS IS LESS THAN 45 INCHES (1143
 MM), THE HORIZONTAL MEMBERS SHALL BE LOCATED ON THE
 SWIMMING POOL SIDE OF THE FENCE. SPACING BETWEEN
 VERTICAL MEMBERS SHALL NOT EXCEED 1 3/4 INCHES (44 MM)
 IN WIDTH. WHERE THERE ARE DECORATIVE CUTOUTS WITHIN
 VERTICAL MEMBERS, SPACING WITHIN THE CUTOUTS SHALL NOT
 EXCEED 1 3/4 INCHES (44 MM) IN WIDTH.
  
 R4501.17.1.5
 WHERE THE BARRIER IS COMPOSED OF HORIZONTAL AND
 VERTICAL MEMBERS AND THE DISTANCE BETWEEN THE TOPS OF
 THE HORIZONTAL MEMBERS IS 45 INCHES (1143 MM) OR MORE,
 SPACING BETWEEN VERTICAL MEMBERS SHALL NOT EXCEED 4
 INCHES (102 MM). WHERE THERE ARE DECORATIVE CUTOUTS
 WITHIN VERTICAL MEMBERS, SPACING WITHIN THE CUTOUTS
 SHALL NOT EXCEED 1 3/4 INCHES (44 MM) IN WIDTH.
  
 R4501.17.1.6
 MAXIMUM MESH SIZE FOR CHAIN LINK FENCES SHALL BE A 21/4
 INCH SQUARE (57 MM) UNLESS THE FENCE IS PROVIDED WITH
 SLATS FASTENED AT THE TOP OR BOTTOM WHICH REDUCE THE
 OPENINGS TO NO MORE THAN 1 3/4 INCHES (44 MM).
  
 R4501.17.1.7
 WHERE THE BARRIER IS COMPOSED OF DIAGONAL MEMBERS, THE
 MAXIMUM OPENING FORMED BY THE DIAGONAL MEMBERS SHALL BE
 NO MORE THAN 13/4 INCHES (44 MM).
  
 R4501.17.1.8
 ACCESS GATES, WHEN PROVIDED, SHALL BE SELF-CLOSING AND
 SHALL COMPLY WITH THE REQUIREMENTS OF SECTIONS
 R4501.17.1.1 THROUGH R4501.17.1.7 AND SHALL BE EQUIPPED
 WITH A SELF-LATCHING LOCKING DEVICE LOCATED ON THE POOL
 SIDE OF THE GATE. WHERE THE DEVICE RELEASE IS LOCATED
 NO LESS THAN 54 INCHES (1372 MM) FROM THE BOTTOM OF THE
 GATE, THE DEVICE RELEASE MECHANISM MAY BE LOCATED ON
 EITHER SIDE OF THE GATE AND SO PLACED THAT IT CANNOT BE
 REACHED BY A YOUNG CHILD OVER THE TOP OR THROUGH ANY
 OPENING OR GAP FROM THE OUTSIDE. GATES THAT PROVIDE
 ACCESS TO THE SWIMMING POOL MUST OPEN OUTWARD AWAY FROM
 THE POOL. THE GATES AND BARRIER SHALL HAVE NO OPENING
 GREATER THAN 1/2 INCH (12.7 MM) WITHIN 18 INCHES (457
 MM) OF THE RELEASE MECHANISM.
  
 R4501.17.1.9
 WHERE A WALL OF A DWELLING SERVES AS PART OF THE
 BARRIER, ONE OF THE FOLLOWING SHALL APPLY:
  
 1. ALL DOORS AND WINDOWS PROVIDING DIRECT ACCESS FROM
 THE HOME TO THE POOL SHALL BE EQUIPPED WITH AN EXIT
 ALARM COMPLYING WITH UL 2017 THAT HAS A MINIMUM SOUND
 PRESSURE RATING OF 85 DBA AT 10 FEET (3048 MM). ANY
 DEACTIVATION SWITCH SHALL BE LOCATED AT LEAST 54 INCHES
 (1372 MM) ABOVE THE THRESHOLD OF THE ACCESS. SEPARATE
 ALARMS ARE NOT REQUIRED FOR EACH DOOR OR WINDOW IF
 SENSORS WIRED TO A CENTRAL ALARM SOUND WHEN CONTACT IS
 BROKEN AT ANY OPENING.
  
 EXCEPTIONS:
  