| Date |
Text |
| 2015-12-21 11:56:40 | 1ST REVIEW: FBC 2014 5TH ED. NEC 2011/RESIDENTIAL |
| | MARIO VALDES |
| | ELECTRICAL PLAN EXAMINER |
| | 516-805-6700 |
| | [email protected] |
| | ALTERNATE CONTACT |
| | MIKE ALBARRAN |
| | 561-805-6746 |
| | [email protected] |
| | |
| | |
| | 1- PROVIDE GFCI PROTECTION IN GARAGE NEC 210.8 |
| | 2-PLEASE ADD TO NOTES FBC ENERGY CODE RESIDENTIAL |
| | SECTION 404.1 |
| | A MINIMUM OF 75 PERCENT OF THE LAMPS IN PERMANENTLY |
| | INSTALLED LIGHTING FIXTURES SHALL BE HIGH-EFFICACY |
| | LAMPS OR A MINIMUM OF 75 PERCENT OF THE PERMANENTLY |
| | INSTALLED LIGHTING FIXTURES SHALL CONTAIN ONLY HIGH |
| | EFFICACY LAMPS. |
| | SHALL BE SEALED AND IC RATED TO PROTECT THERMAL |
| | ENVOLOPE. |
| | 3-CARBON MONOXIODE DETECTORS. EVERY SEPARATE BUILDING |
| | OR AN ADDITION TO AN EXISTING BUILDING FOR WHICH A |
| | PERMIT FOR NEW CONSTRUCTION IS ISSUED AND HAVING A |
| | FOSSIL-FUEL-BURNING HEATER OR APPLIANCE, A FIREPLACE, |
| | AN ATTACHED GARAGE, OR OTHER FEATURE, FIXTURE, OR |
| | ELEMENT THAT EMITS CARBON MONOXIDE AS BYPRODUCT OF |
| | COMBUSTION SHALL HAVE AN OPERATIONAL CARBON MONOXIDE |
| | ALARM INSTALLED WITHIN 10 FEET (3048 MM) OF EACH ROOM |
| | USED FOR SLEEPING PURPOSES. |
| | 4- A/C EQUIPMENT NOT SHOWN IN PLANS FOR DISCONECTING |
| | MEANS PURPOSES AND A 125-VOLT, SINGLE-PHASE, 15- OR 20- |
| | AMPERE-RATED RECEPTACLE OUTLET SHALL BE INSTALLED AT AN |
| | ACCESSIBLE LOCATION FOR THE SERVICING OF HEATING, |
| | AIR-CONDITIONING, |
| | AND REFRIGERATION EQUIPMENT.THE RECEPTACLE SHALL BE |
| | LOCATED ON THE SAME LEVEL AND WITHIN 7.5 M (25 FT) OF |
| | THE HEATING, |
| | AIR-CONDITIONING, AND REFRIGERATION EQUIPMENT. THE |
| | RECEPTACLE OUTLET SHALL NOT BE CONNECTED TO THE LOAD |
| | SIDE OF THE EQUIPMENT |
| | DISCONNECTING MEANS. |
| | 5- RISER DIAGRAM SHOULD BE MORE SPECIFIC IN CONDUIT AND |
| | CONDUCTOR SIZES AND MINIMUM COVER REQUIREMENTS. |
| | DIRECT-BURIED CABLE |
| | OR CONDUIT OR OTHER RACEWAYS SHALL BE INSTALLED TO MEET |
| | THEMINIMUM COVER REQUIREMENTS OF TABLE 300.5. |