| Date |
Text |
| 2015-11-20 07:13:48 | BUILDING PLAN REVIEW |
| | W. P. B. REVISION: 15110656 |
| | W. P. B. PERMIT: 15010789 |
| | ADD: 2600 BROADWAY |
| | CONT: MVP CONTRACTORS |
| | TEL: (954)214-0226 |
| | E-MAIL: [email protected] |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: FRI. NOV. 20/2015 |
| | ACTION: DENIED |
| | |
| | 1) REVISION APPARENTLY THE CONTRACTOR HAS ELECTED TO |
| | CHANGE WINDOWS FROM LARGE MISSILE IMPACT WINDOWS TO |
| | NON-IMPACT GLAZING & MULLIONS. CIRCLE THE WINDOW WIDTH, |
| | LENGHT, PRESSURES, FASTENERS, MULLION SIZE, LENGTH, |
| | TRIBUTARY AREA, IF RE-INFORCEMENT IS REQUIRED AND |
| | FASTENERS. NO NEW WINDOW PRODUCT APPROVAL WAS SUBMITTED |
| | FOR REVIEW OF PRESSURES AND INSTALLATION. 2010 FBC-B |
| | 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.4.1 |
| | COMPONENTS & CLADDING. |
| | |
| | 2) NEITHER THE NON-IMPACT WINDOW PRODUCT APPROVAL NOR |
| | THE STORM SHUTTER (ACCORDIAN) HAVE BEEN REVIEWED BY THE |
| | DESIGNER ARCHITECT RICHARD CHER. |
| | 107.3.4.1 THOSE PRODUCTS WHICH ARE REGULATED BY DCA |
| | RULE 9N-3SHALL BE REVIEWED AND APPROVED IN WRITING BY |
| | THE DESIGNER OF RECORD PRIOR |
| | TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| | |
| | THE REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE |
| | CHARGE SHALL BE RESPONSIBLE FOR REVIEWING AND |
| | COORDINATING SUBMITTAL DOCUMENTS PREPARED BY OTHERS, |
| | INCLUDING PHASED AND DEFERRED SUBMITTAL ITEMS, FOR |
| | COMPATIBILITY WITH THE DESIGN OF THE BUILDING. THOSE |
| | PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3SHALL BE |
| | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF |
| | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | DEVELOPMENT SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| | |
| | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| | |