2015-11-30 13:26:15CORRECT ELECTRICAL CODE REFERENCE IS 2011, NOT 2008.
 ALL DEVICES NOTED IN NOTE 7 ARE TO BE LABELED FOR THE
 LOCATION AS WELL.
 120V WATER HEATER FEED IN NOTE 8 DOES NOT APPEAR ON THE
 PAQNEL SCHEDULE.
 NOTE 16 DOES NOT INDICATETHE EQUIPMENT IT IS
 REFERENCING TO BE CONNECTED.
 NO ENERGY CODE COMPLIANCE FOR FBC-ENERGY APPEARS TO BE
 CONNECTED.
 NO REFERENCE IS MADE TO INDICATE COMPLIANCE WITH THE
 ELECTRICAL REQUIREMENTS OF THE FBC-ENERGY.
 CEILING FANS APPEAR TO BE EXISTING, HOWEVER, NO LOAD OR
 CIRCUITIS INDICATED.
 ARE GFCI RECEPTACLES PROPOSED AT THE BATHROOM BASINS?
 NONE APPEAR TO BE INDICATED.
 NOTES INDICATE AIR CONDITIONING/MECHANICAL WORK. NONE
 IS SHOWN