| Plan Review Notes For Permit 15110375 |
| Permit Number |
15110375 |
|
| Review Stop |
FIRE |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2015-11-20 11:50:09 | 1. PROVIDE RAILING DETAIL FOR MEZZANINE | | | 2. PROVIDE DOOR RATINGS FOR DOORS 04, 05, 06 | | | 3. PROVIDE STAIR DETAIL | | | 4. PROVIDE RATING OF WAREHOUSE WALL THAT PROVIDES | | | SEPARATION TO THE OFFICE SPACE | | | 5. PROVIDE RATING OF STORAGE ROOM WALL THAT PROVIDES | | | SEPERATION FROM THE OFFICE SPACE | | | 6. REVIEW / REVISE FIRST FLOOR EGRESS PLAN (CAN NOT | | | EGRESS FROM LOWER HAZARD THROUGH HIGHER HAZARD | | | 7. STORAGE SHOW UNDER STAIR. PROVIDE DETAIL OF | | | PROTECTION (SPRINKLER, ETC..) | | | 8. SPRINKLER MODIFICATIONS MAY BE NEEDED. HAVE | | | EVALUATED. IF NEEDED SUBMIT UNDER SEPERATE PERMIT. | | | 9. FIRE ALARM MODIFICATIONS MAY BE NEEDED TO MEET | | | NOTIFICATION REQUIREMENTS, HAVE EVALUATED. IF NEEDED | | | SUBMIT UNDER SEPERATE PERMIT. |
|