| 2015-11-21 11:12:53 | 1ST REVIEW: FBC 2014 5TH ED. RESIDENTIAL | | | | | | THE PLAN IS REDUCED AND TOO SMALL TO READ AND TOO SMALL | | | FOR RECORD RETENTION. PLEASE PROVIDE AN ENLARGED PLAN. | | | | | | FBC FBC 107.2.1.4 QUALITY OF BUILDING PLANS. BUILDING | | | PLANS SHALL BE DRAWN TO A MINIMUM 1/8 INCH SCALE UPON | | | SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE MEDIUM. | | | THIS POLICY MAY INCLUDE SUCH THINGS AS MINIMUM SIZE, | | | SHAPE, CONTRAST, CLARITY, OR OTHER ITEMS RELATED TO | | | RECORDS MANAGEMENT. | | | | | | THE WIND DESIGN AND STRUCTURAL ATTACHMENT INFORMATION | | | IS UNCLEAR AND APPEARS GENERIC. SUCH DESIGN MUST BE | | | SITE SPECIFIC. PLEASE PROVIDE THE SPECIFIC APPLICABLE | | | DESIGN PRESSURES AS DETERMINED USING THE METHODS IN | | | FBC-R301.1.3 ENGINEERED DESIGN. PLEASE PROVIDE A | | | SPECIFIC PLAN INDICATING THE LOCATION AND TYPE OF | | | CONNECTORS TO BE INSTALLED. PROVIDE WIND DESIGN | | | CRITERIA FOR THE SPECIFIC GEOGRAPHICAL LOCATION OF THE | | | BUILDING AND CONSIDERING THE PROPOSED LOCATION OF THE | | | SYSTEM ON THE BUILDING. IF DESIGN IS NOT TO BE PROVIDED | | | BY A FLORIDA LICENSED ENGINEER, THEN PROVIDE STRUCTURAL | | | CALCULATIONS TO JUSTIFY THE DESIGN. | | | | | | NAMASTE' | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | (561) 805-6710 | | | [email protected] | | | |
|