| Plan Review Notes For Permit 15101064 |
| Permit Number |
15101064 |
|
| Review Stop |
M |
| Sequence Number |
4 |
|
| Notes |
| Date |
Text |
| 2016-08-24 09:02:59 | 4TH REVIEW FBC-2014 MECHANICAL | | | PERMIT #15101064 | | | 8/24/16 | | | | | | 1) AS PREVIOUSLY REQUESTED, PROVIDE A SEQUENCE OF | | | OPERATION FOR THE SALON EXHAUST FANS. CLARIFY IF THE | | | FANS WILL BE ON SWITCHES, OR LINKED TO THE LIGHTS OR AC | | | SYSTEMS. | | | | | | 2) PROVIDE MAKE UP AIR AND A SEQUENCE OF OPERATION FOR | | | EF-1 IN THE STORAGE ROOM. CLARIFY THE PURPOSE OF THE | | | FAN AND PROVIDE A LIST OF MATERIALS AND QUANTITIES OF | | | MATERIALS TO BE STORED IN THE ROOM. PROVIDE MSDS SHEETS | | | FOR ANY HAZARDOUS TYPE MATERIALS, AND PROVIDE AN | | | EXHAUST VENTILATION CALCULATION- REFER TO SECTION 414 | | | FBC-14 BUILDING FOR APPLICABLE REQUIREMENTS. | | | | | | 3) PROVIDE WIND LOAD ENGINEERING FOR ANCHORAGE OF THE | | | EXHAUST FANS AND CURBS TO THE ROOF STRUCTURE- SECTION | | | 301.15. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|