| Date |
Text |
| 2015-11-09 15:22:41 | BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 15101064 |
| | ADD: 112 N. DIXIE HWY. |
| | CONT: THE PROTINUS CORP |
| | TEL: (561)214-0123 |
| | E-MAIL: THE [email protected] |
| | |
| | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| | FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: MON. NOV. 09/2015 |
| | ACTION: DENIED |
| | |
| | 1) THE COVERSHEET INDICATES THIS TENANT SPACE IS TO BE |
| | A BUSINESS OCCUPANCY. THE LEASABLE SQ. FOOTAGE IS 2685 |
| | S. F. THE OCCUPANT LOAD IS NOT GIVEN AND APPEARS THAT |
| | IT WILL BE GREATER THAN 27 OCCUPANTS. THE DESIGNER OF |
| | RECORD CAN PROVIDE AN INCREASED OCCUPANT LOAD SEE 2014 |
| | FBC-B 1004.2. |
| | |
| | 2) THE COVERSHEET UNDER THE HEADING OF CODE COMPLIANCE |
| | THE DESIGNER OF RECORD HAS NOT PROVIDED TO WHICH METHOD |
| | OF DESIGN THE PLANS WERE DESIGN TO UNDER THE 2014 |
| | EXISTING BUILDING CODE 301.1. APPLICATION OF A METHOD |
| | SHALL BE THE SOLE BASIS FOR ASSESSING THE COMPLIANCE OF |
| | WORK , SEE 301.1 THROUGH 301.1.3. THE DESIGNER IS TO |
| | PICK A COMPLIANCE METHOD OF HOW THE PLANS WERE DERIVED. |
| | |
| | 3) SHEET A-2 SHOWS THE BACK DOORS SWINGING OUT. PLEASE |
| | PROVIDE A SURVEY THAT SHOWS THE PROPERTY LINE. |
| | DOORS CANNOT SWING OUT OVER THE PROPERTY LINE. 2014 |
| | FBC-B 3202.2. |
| | |
| | 4) SHEET A5 DOES SHOW A RECEPTION DESK, NO HEIGHT HAS |
| | BEEN ASSIGNED TO THE DIAGRAM, PLEASE PROVIDE COMPLIANCE |
| | WITH 2014 FBC-ACCESSIBILITY CODE 904.4, 904.4.1 OR |
| | 904.4.2. |
| | |
| | 5) SHEET A5 NO ELEVATIONS HAVE BEEN PROVIDED FOR THE |
| | BREAK ROOM SINK, PLEASE PROVIDE COMPLIANCE WITH 2014 |
| | FBC-ACCESSIBILITY CODE 606.2 THROUGH 606.5. |
| | |
| | 6)) SHEET A5 NO ELEVATIONS HAVE BEEN PROVIDED FOR THE |
| | JUICE BAR. SHEET A2 SHOWS DETAILS ON A5 DETAILS K-M. |
| | PLEASE PROVIDE COMPLIANCE WITH THE 2014 |
| | FBC-ACCESSIBILITY CODE 904.4, 904.4.1 OR 904.4.2. NOTE |
| | IF THERE WILL BE TABLES THEN COMPLIANCE WITH 902.3 WILL |
| | ALSO NEED TO COMPLIED WITH. |
| | |
| | 7) SHEET A-7 THE FINISH SCHEDULE THE RESTROOMS WILL |
| | NEED TO SHOW COMPLIANCE WITH THE 2014 FBC-B 1210.2.2. |
| | |
| | 8) PLEASE NOTE THERE WERE MECHANICAL PLANS PROVIDE, |
| | UNDER THE MECHANICAL REVIEW EXHAUST AIR AND MAKE UP AIR |
| | WILL NEED TO BE SUPPLIED TO THE MANICURE & PEDICURE |
| | STATIONS. NORMALLY THESE FANS ARE MOUNTED ON THE ROOF |
| | AND WILL NEED TO COMPLY WITH; |
| | 8A) M- 301.15 WIND RESISTANCE. MECHANICAL EQUIPMENT, |
| | APPLIANCES AND SUPPORTS THAT ARE EXPOSED TO WIND SHALL |
| | BE DESIGNED AND INSTALLED TO RESIST THE WIND PRESSURES |
| | DETERMINED IN ACCORDANCE WITH THE FLORIDA BUILDING |
| | CODE, BUILDING. |
| | 8B) B-1609.6.4.4.1 COMPONENTS AND CLADDING. WIND |
| | PRESSURE FOR EACH COMPONENT OR CLADDING ELEMENT ARE TO |
| | BE DESIGNED FOR WIND PRESSURES COMPONENTS AND |
| | ATTACHMENTS. |
| | |
| | 8C) 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, |
| | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT |
| | OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) |
| | SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT |
| | WILL REQUIRE PRODUCT APPROVALS: |
| | (31 ( C ) WALL LOUVERS |
| | (D) ROOFING PRODUCTS AND ASSEMBLIES, ROOF TOP CURBS, |
| | EXHAUST & INTAKE FANS |
| | |
| | 8D) 107.3.4.1 THOSE PRODUCTS WHICH ARE REGULATED BY DCA |
| | RULE 9N-3SHALL BE REVIEWED AND APPROVED IN WRITING BY |
| | THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR |
| | JURISDICTIONAL APPROVAL. |
| | |
| | 9) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |