| Date |
Text |
| 2015-10-30 10:10:41 | 1ST REVIEW: FBC 2014 5TH ED. |
| | |
| | I DISCUSSED THE APPLICATION WITH THE CONTACT PERSON AND |
| | CHANGED THE PERMIT DESCRIPTION TO CLARIFY THE SCOPE OF |
| | WORK AND CHANGED THE TYPE TO ROOFING AS THE SCOPE IS A |
| | ROOF REPAIR AROUND THE APPROXIMATE 270 LF PERIMETER OF |
| | THE STRUCTURE AND INCLUDES FASCIA AND 3X3 DRIP EDGE |
| | REPLACEMENT AND THE ADDITION OF 1X2 PT DRIP. THE |
| | SUBMITTAL DOES NOT SPECIFY THE ROOF COVERING REPAIR. |
| | ELI INDICATES THE WORK IS COMPLETE. A 3X FEE PENALTY |
| | HAS BEEN ADDED AS THE RECORD INDICATES INSPECTOR LANGE |
| | PREVIOUSLY ISSUED A RED TAG FOR THE WORK. THE CLAIMED |
| | VALUE OF $2,300.00 APPEARS LOW. THE APPLICATION'S |
| | ASSIGNED CONTRACTOR IS CGC1515166 VINAYAGAR M |
| | BALAKRISHNAN, BUT MUST BE CHANGED TO HIS ROOFING |
| | LICENSE CCC1328728 AS FS 489.105 DEFINITIONS - ROOFING |
| | CONTRACTOR - INCLUDES THE SCOPE OF WORK OF A ROOFING |
| | CONTRACTOR ALSO INCLUDES ANY REPAIR OR REPLACEMENT OF |
| | WOOD ROOF SHEATHING OR FASCIA AS NEEDED DURING ROOF |
| | REPAIR OR REPLACEMENT.. PLEASE PROVIDE THE FOLLOWING |
| | UPON RESUBMITTAL: |
| | |
| | 1-AMEND THE SCOPE OF WORK ON THE APPLICATION TO |
| | ACCURATELY REFLECT THE WORK COMPLETED AND PROVIDE A |
| | COPY OF A ROOFING LICENSE AND INSURANCE IF APPLICABLE |
| | AS DESCRIBED ABOVE. |
| | 2- AMEND THE VALUE APPROPRIATELY AND PROVIDE A COPY OF |
| | THE CONTRACT SHOWING THE SCOPE AND VALUE. |
| | 3- PROVIDE A PLAN, ENGINEERING CALCULATIONS IF |
| | APPLICABLE AND APPLICABLE PRODUCT APPROVAL TO DEPICT |
| | THE WORK COMPLETED, SPECIFY THE ROOFING WORK, THE |
| | LUMNER SPECIES AND GRADE, ALL ATTACHMENTS AND |
| | CONNECTIONS. PROVIDE A CERTIFICATION LETTER FOR |
| | COMPLETED WORK ALTERNATIVELY, PROVIDE A LETTER FROM A |
| | FLORIDA LICENSED PROFESSIONAL ENGINEER DESCRIBING THE |
| | WORK COMPLETED PER THE FORGOING , PROVIDING |
| | CALCULATIONS AS MAY BE NEEDED, AND CERTIFYING THE WORK |
| | AS CODE COMPLIANT. |
| | |
| | THE FOLLOWING FBC 2014 5TH ED CODE SECTIONS APPLY TO |
| | THE ABOVE COMMENTS: |
| | |
| | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
| | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN |
| | UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE |
| | OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE |
| | AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT |
| | IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND |
| | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS |
| | DETERMINED BY THE BUILDING OFFICIAL. SUCH DRAWINGS AND |
| | SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM |
| | OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS, |
| | WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE |
| | TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC, |
| | AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE |
| | OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS |
| | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC |
| | INFORMATION. ALL INFORMATION, DRAWINGS, SPECIFICATIONS |
| | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE |
| | OF THE PERSON RESPONSIBLE FOR THE DESIGN. |
| | |
| | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR ANY ROOFING |
| | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED |
| | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. |
| | |
| | FBC 109.3 BUILDING PERMIT VALUATION. FOR PERMITTING |
| | PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE |
| | TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, |
| | ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, |
| | RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, |
| | MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY |
| | LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST |
| | PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS |
| | SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY |
| | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT |
| | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. |
| | |
| | FBC 110.1 GENERAL. CONSTRUCTION OR WORK FOR WHICH A |
| | PERMIT IS REQUIRED SHALL BE SUBJECT TO INSPECTION BY |
| | THE BUILDING OFFICIAL AND SUCH CONSTRUCTION OR WORK |
| | SHALL REMAIN ACCESSIBLE AND EXPOSED FOR INSPECTION |
| | PURPOSES UNTIL APPROVED. |
| | |
| | FBC 117 - THE BUILDING OFFICIAL MAY REQUIRE TESTS OR |
| | TEST REPORTS AS PROOF OF COMPLIANCE. REQUIRED TESTS ARE |
| | TO BE MADE AT THE EXPENSE OF THE OWNER, OR AGENT, BY AN |
| | APPROVED TESTING LABORATORY OR OTHER APPROVED AGENCY. |
| | |
| | STEVEN KENNEDY, CBO |
| | CHIEF PLANS EXAMINER |
| | (561) 805-6710 |
| | [email protected] |
| | |