| Plan Review Notes For Permit 15101027 |
| Permit Number |
15101027 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2015-11-23 14:03:23 | 11/23/15 ON MALBARRAN'S DESK. CP | | 2015-11-16 12:52:30 | 1) FOR A BUSINESS OCCUPANCY WITH AN OCCUPANT LOAD OF 59 | | | PERSONS A TOTAL OF 2 WATER CLOSETS ARE REQUIRED FOR THE | | | MALES AND 2 WATER CLOSETS ARE REQUIRED FOR THE FEMALES | | | PER TABLE 403.1 OF THE 2014 FBC-PLUMBING. | | | 2) A DRINKING FOUNTAIN IS REQUIRED PER 2014 | | | FBC-PLUMBING TABLE 403.1. A MINIMUM OF 2 DRINKING | | | FOUNTAINS ARE REQUIRED PER TABLE 403.1 FOOTNOTE (E) AND | | | THE 2014 FBC-ACCESSIBILITY SEC.211.2. | | | 3) SEE BUILDING PLAN REVIEW COMMENT REGARDING THE | | | OCCUPANCY TYPE OF THIS SPACE. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | |
|