| Date |
Text |
| 2015-12-09 11:46:59 | BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 15100589 |
| | ADD: 1600 N DIXIE HWY. |
| | CONT: RJS CONSTRUCTION GROUP, INC. |
| | TEL: (561)795-4712 |
| | E-MAIL: [email protected] |
| | |
| | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| | FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: MON. NOV. 02/2015 |
| | ACTION: DENIED |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | |
| | 1) COMPLIED. THE A2.3 & M2 SHEETS SHOW 3 NEW RTU UNITS |
| | ON THE EXISITNG ROOF TOP. PLEASE PROVIDE A ROOF FRAMING |
| | PLAN SHOWING THE NEW ROOF TOP OPENINGS THE NEW FRAMING |
| | MEMBERS, HEADERS, HANGERS AND OR BUCKETS FOR THE NEW |
| | OPENINGS. 2014 FBC-B 2308.10.4.3. |
| | |
| | 2) 2ND REQUEST. PLEASE PROVIDE THE PRODUCT APPROVALS |
| | FOR THE NEW RTU ROOF TOP CURBS, ROOF PATCHING AROUND |
| | THE CURBS AND NEW EXHAUST VENT. 2014 FBC-B 1609.1.2 |
| | PROTECTION OF OPENINGS, 1609.6.4.4.1 COMPONENTS & |
| | CLADDING. FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE |
| | 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR |
| | CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT |
| | APPROVALS: |
| | (31)(D) ROOFING PRODUCTS AND ASSEMBLIES/ AND ROOF TOP |
| | RTU CURBS |
| | |
| | 3) 2ND REQUEST. 107.3.4.1 THOSE PRODUCTS WHICH ARE |
| | REGULATED BY DCA RULE 9N-3SHALL BE REVIEWED AND |
| | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO |
| | SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| | |
| | 4) COMPLIED. |
| | |
| | 5) 2ND REQUEST. PLEASE PROVIDE ENERGYY CALCULATIONS IN |
| | ACCORDANCE WITH 2014 ENERGY CODE SECTION C101.4.3. SEE |
| | MECHANICAL COMMENTS. |
| | |
| | 6) COMPLIED. SHEET A2.1 DOES NOT INDICATE THE TYPE OF |
| | ROOF DECK NOR FRAMING. THIS STRUCTURE HAS WOOD 2X'S AND |
| | WOOD DECK. THE NEW TENANT SEPARATION WALL WILL NEED TO |
| | GO ALL THE WAY TO THE ROOF DECK. PLEASE PROVIDE A |
| | DETAIL OF HOW THE FIRE RATING WILL BE MAINTAINED TO THE |
| | ROOF DECK. THIS WILL BE DISSIMILAR MATERIALS, WILL ALSO |
| | NEED TO BE A FLEXIBLE CONNECTION BECAUSE OF THE HEATING |
| | AND COOLING OF THE ROOF DECK. PLEASE SHOW COMPLIANCE |
| | WITH 2014 FBC-B 708.8 JOINTS MADE IN OR BETWEEN FIRE |
| | BARRIERS SHALL COMPLY WITH 715. |
| | |
| | 7) NEW COMMENT, THIS IS AN UNUSAL BUILDING SINCE NONE |
| | OF THE TENANT SPACES HAVE DOORWAYS THAT EXIT ONTO A |
| | PUBLIC RIGHT OF WAY. PLEASE PROVIDE A SITE PLAN SHOWING |
| | COMPLIANCE WITH: |
| | 2014 FBC-B 1027.5 ACCESS TO A PUBLIC WAY. THE EXIT |
| | DISCHARGE SHALL PROVIDE A DIRECT AND UNOBSTRUCTED |
| | ACCESS TO A PUBLIC WAY. |
| | 2014 FBC-ACCESSIBILITY CODE 206.2.4 SPACES AND |
| | ELEMENTS. AT LEAST ONE ACCESSIBLE ROUTE SHALL CONNECT |
| | ACCESSIBLE BUILDING OR FACILITY ENTRANCES WITH ALL |
| | ACCESSIBLE SPACES AND ELEMENTS WITHIN THE BUILDING OR |
| | FACILITY WHICH ARE OTHERWISE CONNECTED BY A CIRCULATION |
| | PATH TO THE PUBLIC WAY, UNLESS EXEMPTED BY 206.2.3 |
| | EXCEPTIONS 1 THROUGH 7. |
| | 2014 FBC-ACCESSIBILITY 208.3.1 WHERE IN THE ACCESSIBLE |
| | PARKING SPACE AND ACCESS AISLE THE PATRON IS NOT |
| | COMPELLED TO WALK OR WHEEL BEHIND PARKED CARS. |
| | |
| | 8) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |