| Plan Review Notes For Permit 15100353 |
| Permit Number |
15100353 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2015-10-13 10:15:43 | 1ST REVIEW: FBC 2014 BUILDING | | | PERMIT #15100353 | | | 10/13/15 | | | | | | 1) PROVIDE ENGINEERING FOR ROOF TO WALL CONNECTION | | | IMPROVEMENTS AS REQUIRED BY SECTION 708.8 FBC-14 | | | EXISITING BUILDING CODE. REFER TO SECTIONS 708.8.1.1- | | | 708.8.1.7 FOR MATERIALS AND METHODS. | | | 2) PLEASE CORRECT THE EXPOSURE B CATEGORY SELECTION AND | | | FASTENING REQUIREMENTS ON PAGE 13 OF THE CERTAINTEEN | | | PRODUCT APPROVAL. THE HOME IS LOCATED IN AN EXPOSURE D | | | CATEGORY PER SECTION R301.2.1.4 FBC-14. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|