Plan Review Notes
Plan Review Notes For Permit 15090855
Permit Number 15090855
Review Stop P
Sequence Number 1
Notes
Date Text
2015-10-03 05:49:521) SHT. P101- THE GREASE TRAP SIZING CALCULATIONS REFER
 TO THE 2010 FLORIDA PLUMBING CODE. REVISE THE NOTE TO
 READ THE 2014 FLORIDA PLUMBING CODE.
 2) ANY FLOOR DRAIN NOT RECEIVING THE DISCHARGE OF AN
 INDIRECT WASTE SHALL BE EQUIPPED WITH A TRAP PRIMER PER
 FBC-PLUMBING SEC.1002.4.
 3) CLEANOUTS ARE REQUIRED ON THE RISERS FOR THE ISLAND
 VENT PER 2014 FBC- PLUMBING SEC.916.3.
 4) SHOW FIXTURES # K28, K32 & K73 ON THE SANITARY
 DRAINAGE PLAN.
 5) SHOW THE LOCATION OF THE GREASE TRAPS ON THE PLAN.
 WPB AMEND. TO FBC SEC. 107.2.1.
 6) ARE THE GREASE TRAPS SERVING ANY OTHER RESTAURANT
 BESIDES THIS ONE?. INDICATE ON THE PLANS. IF SO, SUBMIT
 REVISED SIZING CALCS.
 7) SHT. P103-DETAIL #5 - INDICATE ON THE PLAN HOW THE
 GAS PIPE SUPPORTS WILL BE ATTACHED TO THE ROOF.
 8) INDICATE THE TYPE OF GAS PIPE TO BE INSTALLED.
 9) SUBMIT MANUF. SPECS FOR THE GAS REGULATORS.
 10) SUBMIT MANUF. SPECS ON ALL GAS EQUIPMENT. EQUIPMENT
 SHALL BE LISTED AND LABELED PER FBC-GAS SEC. 301.3.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  