| Date |
Text |
| 2015-10-14 18:55:19 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL |
| | BUILDING PLANS EXAMINER |
| | [email protected] |
| | 561-805-6724 |
| | |
| | 1. OK |
| | |
| | 2. PROVIDE INFORMATION REGARDING EXISTING CONDITIONS, |
| | FBC 107 (IN THE FORM OF A PLAN) AND PROPOSED. NO |
| | INFORMATION REGARDING THE TENANT SPACE HAS BEEN |
| | PROPOSED. |
| | |
| | 3. PROVIDE INFORMATION AS TO HOW THE PROPOSED |
| | IMPROVEMENT WILL AFFECT EXITING AND ACCESSIBILITY. SPEC |
| | SHEET STATES THAT THE DOOR WILL BE INSTALLED WITHIN A |
| | 3/4" RECESS. PROVIDE A PLAN/DETAIL WHICH SHOWS THAT |
| | THIS RECESS COMPLIES WITH MEANS OF EGRESS AND |
| | ACCESSIBILITY REQUIREMENTS. WON'T THIS CREATE A 3/4" |
| | TRENCH? SEE FBC 5TH EDITION ACCESSIBILITY 303. IS THIS |
| | AREA RQUIRED TO BE ACCESSIBLE? SHOW COMPLIANCE WITH FBC |
| | 1008.1, 1008.1.4.3. NOT ENOUGH INFORMATION PROVIDED TO |
| | PERFORM A COMPLETE PLAN REVIEW, FBC 107. |
| | |
| | 2ND REVIEW, PROVIDE A DETAIL WHICH SHOWS THE AFFECT ON |
| | ACCESSIBILITY AND EXITING. A PLAN WAS PROVIDED WHICH |
| | STATES THAT THIS WILL BE INSTALLED IN A TRENCH, BUT THE |
| | SPEC SHEET PROVIDED STATES THAT THIS SLIDING GLASS DOOR |
| | HAS A 2 1/4" RISER FOR THE TRACK. |
| | |
| | SEE FBC 107 REGARDING THE QUALITY OF DETAIL. PLANS TO |
| | BE ARCHITECTURAL QUALITY, TO SCALE. A STATEMENT THAT |
| | THIS IS WHEELCHAIR ACCESSIBLE IS NOT ADEQUATE TO |
| | DEMONSTRATE HOW THIS TRACK AND SILL WILL AFFECT |
| | EXITING. |
| | |
| | DETAILS ARE TO SHOW HEIGHT OF SILL, WIDTH, DEPTH, PLAN |
| | VIEW AND SECTION, WITH DIMENSIONS. DIMENSIONS ARE TO BE |
| | CONSISTENT WITH THE MANUFACTURER'S INFORMATION. |
| | |
| | |
| | |