| Date |
Text |
| 2015-11-14 08:38:23 | BUILDING PLAN REVIEW |
| | W. P. B. REVISION: 15090594 |
| | W. P. B. PERMIT: 14120130 |
| | ADD: 1901 S. DIXIE HWY. |
| | CONT: SISCA |
| | TEL: ( |
| | E-MAIL: |
| | |
| | 2010 FLORIDA BUILDING CODE W 2010 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| | FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 2ND REVIEW |
| | DATE: SAT.NOV. /2015 |
| | |
| | ACTION: BUILDING PROVISO |
| | |
| | |
| | |
| | 1) COMPLIED. SHEET A1.2 THE NEW LAYOUT OF FURNATURE AND |
| | EGRESS PLAN. |
| | |
| | 2) BUILDING APPROVED WITH EXCEPTION! |
| | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO |
| | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO |
| | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE |
| | ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE |
| | ADDITIONAL REVIEWS WITH ASSOCIATED FEES. |
| | |
| | OF THE PERMITED SET OF DRAWINGS SHEET A4.0 ONLY SHOWS |
| | THE LOCATION OF THE ROOFTOP RTU UNITS. BOTH S3 & M1.3 |
| | BOTH SHOW A ROOF TOP VEIW OF THE PROJECT THE 3 RTU'S |
| | AND INTAKE AND ROOF TOP EXHAUST FANS. THERE IS A NOTE |
| | THE WALKIN CONDENSING UNIT TO BE REMOTE. FINAL LOCATIN |
| | SHALL BE DETERMINED BY OWNER/ ARCHITECT. REVISION # |
| | 15090594 DOES NOT SHOW A REVISION TO THE ROOF PLAN NOR |
| | WAS SHEET S3 UPDATED TO SHOW NEW LOCATIONS, SHEET M1.3 |
| | DOES SHOW ON THE MECHANICAL ROOF TOP SHEET A REVISION |
| | SHOWING THE LOCATION FOR 3 NEWLY LOCATED, (NOT |
| | HIGHLIGHTED SHOWING A REVISION), ROOF TOP CU UNITS, NO |
| | DETAILS UNDER MECHANICAL NOR STRUCTURAL SHEETS!!!!! |
| | PLEASE UPDATE ALL RELEVENT SHEETS TO THE NEW LOCATION |
| | OF THE 3 NEWLY LOCATED ROOF TOP A/C SPLIT SYSTEMS. WITH |
| | 3 CU SPLIT SYSTEMS IF A ROOF TOP A/C STAND IS TO BE |
| | INSTALLED. PLEASE PROVIDE THE ATTACHMENT OF THE STAND |
| | TO THIS SITE SPECIFIC CONDITION. ALSO PROVIDE |
| | ENGINEERING FOR HOW THE C/U UNIT WILL BE ATTACHED TO |
| | THE STAND, BY THE ENGINEER OF RECORD. |
| | |
| | THE STRUCTURAL ENGINEER HAS NOT INDICATED ON ANY PLANS |
| | HOW THIS UNIT WILL ATTACH TO THE MWFRS. THE ENGINEER |
| | HAS PROVIDED (PERMIT SET OF DRAWINGS) DETAILS ON SHEET |
| | S6 FOR THE ATTACHMENT OF THE RTU'S CURB TO THE MWFRS |
| | AND THE CLIP SYSTEM FOR MOUNTING THE RTU TO THE CURB. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |