2015-11-23 14:06:1711/23/15 ON MALBARRAN'S DESK. CP
2015-11-12 11:33:25BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15090205
 ADD: 2497 OKEECHOBEE BLVD SUITE # ????????
 CONT: TBD
 TEL: ( 407)654-2521 / RACHEL MEYERS
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W
 * 2014 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION,
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: THURS. NOV. 12/2015
 ACTION: DENIED
  
 1)2ND REQUEST. NOTE ONLY ONE ORIGINAL SIGNED & SEALED
 COVER SHEET WAS SUBMITTED. STRUCTURAL CALCULATIONS BY
 JOHN DIDONONATO P. E. ARE COPIES NOT ORIGINAL
 SIGNATURES PLEASE SUBMIT (3) ORIGINAL SIGNED AND SEALED
 DOCUMENTS. THIS PROJECT WILL REQUIRE 3 OF ALL DOCUMENTS
 SINCE THERE WILL BE A RESIDENT INSPECTOR.
 PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS
 PREPARED BY THE DESIGN PROFESSIONAL AND BEING FILED FOR
 PUBLIC RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE
 DESIGN PROFESSIONAL AFFIXED TO THE DOCUMENT.
 61G15-23.002(2) FL. ADMIN. CODE.
  
 2) 2ND REQUEST. NOTE ONLY ONE ORIGINAL SIGNED & SEALED
 COVER SHEET WAS SUBMITTED. STRUCTURAL CALCULATIONS
 PREPARED BY JOHN DIDONONATO P. E. DO NOT HAVE EACH PAGE
 SEALED. 61G15-23.002(2) FL. ADMIN. CODE. A COVER SHEET
 OR INDEX SHEET FOR ENGINEERING SPECIFICATIONS MAY BE
 USED AND THAT SHEET MUST BE SIGNED IN RESPONSIBLE
 CHARGE OF THE PRODUCTION & PREPARATION OF EACH SECTION
 OF THE ENGINEERING SPECIFICATION WITH SUFFICIENT
 INFORMATION ON THE COVER SHEET OR INDEX LISTING HOW
 MANY PAGES ARE COVERED UNDER THE COVER SHEET OR INDEX
 SHEET.
  
 3)SEMI-COMPLIED. THE MEAN ROOF HEIGHT HAS BEEN
 PROVIDED, THE CORRECT WIND EXPOSURE IS A C EXPOSURE, IF
 THE DESIGNER OF RECORD WISHES TO DESIGN THE STRUCTURE
 TO EXPOSURE D WITH THE HIGHER POSITIVE AND NEGATIVE
 PRESSURES WE WILL REVIEW AS SUCH. SHEET S0.1 PROVIDE
 THE WIND DESIGN CRITERIA AS 170 VULT, EXPOSURE D, WHAT
 IS NOT PROVIDED IS THE MEAN ROOF HEIGHT OF THE
 STRUCTURE FOR THE ADJUSTMENT FACTORS FOR HEIGHT &
 EXPOSURE, 2014 FBC-B TABLE 1609.7(2).
  
 4) 2ND REQUEST. TO DATE THERE IS ONLY THE WIND DESIGN
 CRITERIA, THERE HAS BEEN NO WIND CHARTS SHOWING THE
 PRESSURES FOR ZONES 1-5 FOR THE VARIOUS SQUARE FEET. 10
 SQ. FT., 20 SQ. FT. 50 SQ. FT., & 100 SQ. FT.
 THE PLANS DO NOT PROVIDE THE HEIGHT OF THE BUILDING
 (MEAN ROOF HEIGHT. 2014 FBC-B TABLE 1609.7(2). PLEASE
 PROVIDE THE WIND DESIGN PRESSURES IN VASD SINCE ALL
 PRODUCT APPROVALS ARE IN VASD. 2014 FBC-B 1609.3.
  
 5) COMPLIED. DEFERRED SUBMITTAL. SUBMITTED PRODUCT
 APPROVALS WILL BE RETURNED NOT REVIEWED NOR STAMPED.
 . 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS,
 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT
 OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31)
 SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT
 WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS.
 (B) WINDOWS
 (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL
 LOUVERS, LINTELS & EFIS SYSTEMS,
 (D) ROOFING PRODUCTS AND ASSEMBLIES
 (G) PRE-ENGINEERED A/C STANDS
  
 6)COMPLIED. DEFERRED SUBMITTAL.. 2010 FBC 107.3.4.1
 PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE REGULATED
 BY THE DCA RULE 9N-03 SHALL BE REVIEWED AND APPROVED IN
 WRITING BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL. FL 61G1-23.015 (2) THE
 ARCHITECT IS RESPONSIBLE FOR SUPERVISING AND REVIEWING
 ALL PROJECT DATA, REPORTS, SHOP DRAWINGS ETC..
  
 EITHER THE DESIGNER OF RECORD OR CONTRACTOR CAN DEFER
 THE PRODUCT APPROVALS TO BE SUBMITTED AFTER PERMIT
 ISSUANCE AS A DEFERRED SUBMITTAL AS LONG AS THE
 PRESSURES ON THE BUILDING ARE CORRECT PLEASE REQUEST IN
 WRITING AS PART OF THE PERMIT DOCUMENTS. 107.3.4.2
 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS SECTION,
 DEFERRED SUBMITTALS ARE DEFINED AS THOSE PORTIONS OF
 THE DESIGN THAT ARE NOT SUBMITTED AT THE TIME OF THE
 APPLICATION AND THAT ARE TO BE SUBMITTED TO THE
 BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. DEFERRAL
 OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR APPROVAL OF
 THE BUILDING OFFICIAL. THE
 REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE
 SHALL LIST THE DEFERRED SUBMITTALS ON THE CONSTRUCTION
 DOCUMENTS FOR REVIEW BY THE BUILDING OFFICIAL.
 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
 SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD
 THEM TO THE BUILDING OFFICIAL WITH A NOTATION
 INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO
 THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL
 ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED
 SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING
 OFFICIAL.
  
 7)2ND REQUEST. PLEASE NOTE THAT WELDED AND BOLTED
 CONNECTIONS WILL REQUIRE EITHER THIRD PARTY
 CERTIFICATION OR A RESIDENT INSPECTOR. PLEASE PROVIDE
 WHICH THE DESIGNER OF RECORD OR THE CONTRACTOR WISHES
 TO USE ON THIS PROJECT. IF A RESIDENT INSPECTOR IS
 CHOSEN, FORMS WILL BE E-MAILED FOR THE REQUIRED
 SIGNATURES BY ALL INVOLVED PARTIES. 110.3.9 OTHER
 INSPECTIONS SERVICES.
  
 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION, 110.3.9 OTHER
 INSPECTIONS SERVICES. THE BUILDING OFFICIAL MAY MAKE,
 OR CAUSE TO BE MADE BY OTHERS, THE INSPECTIONS REQUIRED
 BY SECTION 109. HE/SHE MAY ACCEPT REPORTS OF INSPECTORS
 OF RECOGNIZED INSPECTION SERVICES, PROVIDED THAT AFTER
 INVESTIGATION HE/SHE IS SATISFIED AS TO THEIR
 QUALIFICATIONS AND RELIABILITY. A CERTIFICATE CALLED
 FOR BY ANY PROVISION OF THE TECHNICAL CODES SHALL NOT
 BE BASED ON SUCH REPORTS UNLESS THE SAME ARE IN WRITING
 AND CERTIFIED BY A RESPONSIBLE OFFICER OF SUCH SERVICE.
 THE BUILDING OFFICIAL MAY REQUIRE THE OWNER TO EMPLOY
 AN INSPECTION SERVICE IN THE FOLLOWING INSTANCES:
  
 1. FOR BUILDINGS OR ADDITIONS OF TYPE I OR II
 CONSTRUCTION
 2. FOR ALL MAJOR STRUCTURAL ALTERATIONS
 3. WHERE THE CONCRETE DESIGN IS BASED ON COMPRESSIVE
 STRENGTH (F ?C) IN EXCESS OF 3000
 POUNDS PER SQUARE INCH
 4. FOR PILE DRIVING
 5. FOR BUILDINGS WITH AREA GREATER THAN 20,000 SQUARE
 FOOT
 6. FOR BUILDINGS MORE THAN 2 STORIES IN HEIGHT
 7. FOR BUILDINGS AND STRUCTURES OF UNUSUAL DESIGN OR
 METHODS OF CONSTRUCTION
  
 7A) RESIDENT INSPECTOR FORMS MUST BE SIGNED BY ALL
 PARTIES NOTARIZED AND RETURNED TO THE BUILDING
 DEPARTMENT.
  
 7B) FOR THE RESIDENT INSPECTOR PLEASE PROVIDE A RESUME'
 OF INSPECTION EXPERIENCE ON PREVIOUS PROJECT. THE
 RESUME' MUST BE ACCOMPANIED BY ALL CERTIFICATES AS
 SPECIFIED HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE
 WILL REVIEW THE RESUME'. AFTER THE RESUME' IS REVIEWED,
 AN INTERVIEW WILL BE SCHEDULED. UNDER NO CIRCUMSTANCES
 WILL AN INSPECTOR BE INTERVIEWED FOR WORK WITHOUT FIRST
 MEETING THE ABOVE CRITERIA.
 CONTACT: KEN CONRAD
 TEL: 561-805-6666
 E-MAIL: [email protected]
  
 7C) THE CONTRACTOR WILL PRODUCE A JOB SUMMARY OR
 HISTORY FOR THIS TYPE OF CONSTRUCTION. THIS MAY BE
 SUBMITTED TO KEN CONRAD BY E-MAIL. KEN CONRAD:
 [email protected]
  
 7D) NOTE FOR PAPER PLANS 3 SETS OF DOCUMENTS ARE
 REQUIRED. FOR DIGITAL PLANS, AFTER PERMIT ISSUANCE, THE
 PERMIT LIBRARIAN WILL E-MAIL YOU, THE APPROVED AND
 BATCH STAMPED PLANS SO YOU MAY PRINT YOUR PLANS, TWO
 SETS OF PLANS WILL NEED TO BE PRINTED IN COLOR, (1) FOR
 THE RESIDENT INSPECTOR, THE OTHER FOR THE MEP
 INSPECTORS.
  
 7E) PLEASE CALL THE CITY OF WEST PALM BEACH?S AUTOMATED
 TELEPHONE INSPECTIONS LINE (561) 805-6700) FOR
 IN-PROGRESS INSPECTIONS FOR AUDITING OF JOBSITE
 INSPECTIONS.
  
 8) COMPLIED. SHEET S5.1 DETAIL 8 PROVIDES THE
 ATTACHMENT OF THE CURB, WOOD BLOCKING MEMBERS AND TO
 THE STEEL FRAMING MEMBERS. THE MECHANICAL SHEET M1.2
 SHOWS A FEW DETAILS OF ROOF TOP CURBS FOR THE NEW RTU'S
 ON THE ROOF BUT THERE IS NO ANCHORING DETAIL FOR THE
 CURBS, THE STRUCTURAL SHEETS DO NOT HAVE ANY ANCHORING
 DETAILS FOR THE ROOF TOP CURBS. COMPONENTS AND CLADDING
 ROOF TOP CURBS 1609.1.2.
  
 9) 2ND REQUEST. SEMI-COMPLIED. THERE IS A DIFFERENCE IN
 HOW THE RTU UNIT IS TO BE ATTACHED BETWEEN SHEET A2.0
 DETAIL # 1 AND SHEET S5.1 DETAIL # 8 THEY DO NOT MATCH
 UP. 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED. THE
 MECHANICAL NOR STRUCTURAL PLANS PROVIDE THE ATTACHMENT
 OF THE RTU TO THE CURB. PLEASE SHOW COMPLIANCE WITH
 COMPONENTS & CLADDING 1609.1.2.
  
 10) COMPLIED. SHEET S1.1 SHOWS THE EXISTING AND NEW
 LAYOUT FOR NEW RTU'S ON THE ROOF. NEITHER THE A OR S
 PLANS INDICATE HOW COMPLIANCE WITH 2014 FBC-B SECTION
 1509.6.4 EQUIPMENT AND APPLIANCES ON ROOFS OR ELEVATED
 STRUCTURES. WHERE EQUIPMENT AND APPLIANCES REQUIRING
 ACCESS ARE INSTALLED ON ROOFS OR ELEVATED STRUCTURES AT
 A HEIGHT EXCEEDING 16 FEET (4877 MM), SUCH ACCESS SHALL
 BE PROVIDED BY A PERMANENT APPROVED MEANS OF ACCESS,
 THE EXTENT OF WHICH SHALL BE FROM GRADE OR FLOOR LEVEL
 TO THE EQUIPMENT AND APPLIANCES? LEVEL SERVICE SPACE.
 SUCH ACCESS SHALL NOT REQUIRE CLIMBING OVER
 OBSTRUCTIONS GREATER THAN 30 INCHES (762 MM) HIGH OR
 WALKING ON ROOFS HAVING A SLOPE GREATER THAN 4 UNITS
 VERTICAL IN 12 UNITS HORIZONTAL (33-PERCENT SLOPE).
 PERMANENT LADDERS INSTALLED TO PROVIDE THE REQUIRED
 ACCESS SHALL COMPLY WITH THE FOLLOWING MINIMUM DESIGN
 CRITERIA:
 10.1. THE SIDE RAILING SHALL EXTEND ABOVE THE PARAPET
 OR ROOF EDGE NOT LESS THAN 30 INCHES (762 MM).
 10.2. LADDERS SHALL HAVE RUNG SPACING NOT TO EXCEED 14
 INCHES (356 MM) ON CENTER.
 10.3. LADDERS SHALL HAVE A TOE SPACING NOT LESS THAN
 6-INCHES (152 MM) DEEP.
 10.4. THERE SHALL BE A MINIMUM OF 18 INCHES (457 MM)
 BETWEEN RAILS.
 10.5. RUNGS SHALL HAVE A MINIMUM 0.75-INCH (19 MM)
 DIAMETER AND BE CAPABLE OF WITHSTANDING A 300-POUND
 (136.1 KG) LOAD.
 10.6. LADDERS OVER 30 FEET (9144 MM) IN HEIGHT SHALL BE
 PROVIDED WITH OFFSET SECTIONS AND LANDINGS CAPABLE OF
 WITHSTANDING 100 POUNDS PER SQUARE FOOT (488.2 KG/M2).
 10.7. LADDERS SHALL BE PROTECTED AGAINST CORROSION BY
 APPROVED MEANS. CATWALKS INSTALLED TO PROVIDE THE
 REQUIRED ACCESS SHALL BE NOT LESS THAN 24-INCHES (610
 MM) WIDE AND SHALL HAVE RAILINGS AS REQUIRED FOR
 SERVICE PLATFORMS.
  
 11) COMPLIED. ZONING COMMENTS INDICATE THERE MAY HAVE A
 NEED TO SCREEN THE MECHANICAL EQUIPMENT ON THE ROOF.
 PLEASE SHOW COMPLIANCE WITH? 1509.6.1 HEIGHT
 LIMITATIONS.
 MECHANICAL EQUIPMENT SCREENS SHALL NOT EXCEED 18 FEET
 (5486 MM) IN HEIGHT ABOVE THE ROOF DECK, AS MEASURED TO
 THE HIGHEST POINT ON THE MECHANICAL EQUIPMENT SCREEN.
 PLEASE PROVIDE THE ATTACHMENT FOR SCREEN FRAMING AS
 WELL AS THE SCREEN MATERIAL ITSELF, SHOW COMPLIANCE
 WITH 1609.6 WIND DESIGN.
  
 12) WHEN RESUBMITTING PLANS PLEASE INDICATE THE
 REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES
 AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  