| 2015-11-23 14:06:17 | 11/23/15 ON MALBARRAN'S DESK. CP |
| 2015-11-12 11:33:25 | BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 15090205 |
| | ADD: 2497 OKEECHOBEE BLVD SUITE # ???????? |
| | CONT: TBD |
| | TEL: ( 407)654-2521 / RACHEL MEYERS |
| | E-MAIL: [email protected] |
| | |
| | 2014 FLORIDA BUILDING CODE W |
| | * 2014 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, |
| | |
| | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| | FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 2ND REVIEW |
| | DATE: THURS. NOV. 12/2015 |
| | ACTION: DENIED |
| | |
| | 1)2ND REQUEST. NOTE ONLY ONE ORIGINAL SIGNED & SEALED |
| | COVER SHEET WAS SUBMITTED. STRUCTURAL CALCULATIONS BY |
| | JOHN DIDONONATO P. E. ARE COPIES NOT ORIGINAL |
| | SIGNATURES PLEASE SUBMIT (3) ORIGINAL SIGNED AND SEALED |
| | DOCUMENTS. THIS PROJECT WILL REQUIRE 3 OF ALL DOCUMENTS |
| | SINCE THERE WILL BE A RESIDENT INSPECTOR. |
| | PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS |
| | PREPARED BY THE DESIGN PROFESSIONAL AND BEING FILED FOR |
| | PUBLIC RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE |
| | DESIGN PROFESSIONAL AFFIXED TO THE DOCUMENT. |
| | 61G15-23.002(2) FL. ADMIN. CODE. |
| | |
| | 2) 2ND REQUEST. NOTE ONLY ONE ORIGINAL SIGNED & SEALED |
| | COVER SHEET WAS SUBMITTED. STRUCTURAL CALCULATIONS |
| | PREPARED BY JOHN DIDONONATO P. E. DO NOT HAVE EACH PAGE |
| | SEALED. 61G15-23.002(2) FL. ADMIN. CODE. A COVER SHEET |
| | OR INDEX SHEET FOR ENGINEERING SPECIFICATIONS MAY BE |
| | USED AND THAT SHEET MUST BE SIGNED IN RESPONSIBLE |
| | CHARGE OF THE PRODUCTION & PREPARATION OF EACH SECTION |
| | OF THE ENGINEERING SPECIFICATION WITH SUFFICIENT |
| | INFORMATION ON THE COVER SHEET OR INDEX LISTING HOW |
| | MANY PAGES ARE COVERED UNDER THE COVER SHEET OR INDEX |
| | SHEET. |
| | |
| | 3)SEMI-COMPLIED. THE MEAN ROOF HEIGHT HAS BEEN |
| | PROVIDED, THE CORRECT WIND EXPOSURE IS A C EXPOSURE, IF |
| | THE DESIGNER OF RECORD WISHES TO DESIGN THE STRUCTURE |
| | TO EXPOSURE D WITH THE HIGHER POSITIVE AND NEGATIVE |
| | PRESSURES WE WILL REVIEW AS SUCH. SHEET S0.1 PROVIDE |
| | THE WIND DESIGN CRITERIA AS 170 VULT, EXPOSURE D, WHAT |
| | IS NOT PROVIDED IS THE MEAN ROOF HEIGHT OF THE |
| | STRUCTURE FOR THE ADJUSTMENT FACTORS FOR HEIGHT & |
| | EXPOSURE, 2014 FBC-B TABLE 1609.7(2). |
| | |
| | 4) 2ND REQUEST. TO DATE THERE IS ONLY THE WIND DESIGN |
| | CRITERIA, THERE HAS BEEN NO WIND CHARTS SHOWING THE |
| | PRESSURES FOR ZONES 1-5 FOR THE VARIOUS SQUARE FEET. 10 |
| | SQ. FT., 20 SQ. FT. 50 SQ. FT., & 100 SQ. FT. |
| | THE PLANS DO NOT PROVIDE THE HEIGHT OF THE BUILDING |
| | (MEAN ROOF HEIGHT. 2014 FBC-B TABLE 1609.7(2). PLEASE |
| | PROVIDE THE WIND DESIGN PRESSURES IN VASD SINCE ALL |
| | PRODUCT APPROVALS ARE IN VASD. 2014 FBC-B 1609.3. |
| | |
| | 5) COMPLIED. DEFERRED SUBMITTAL. SUBMITTED PRODUCT |
| | APPROVALS WILL BE RETURNED NOT REVIEWED NOR STAMPED. |
| | . 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, |
| | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT |
| | OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) |
| | SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT |
| | WILL REQUIRE PRODUCT APPROVALS: |
| | (31)(A) EXTERIOR DOORS. |
| | (B) WINDOWS |
| | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL |
| | LOUVERS, LINTELS & EFIS SYSTEMS, |
| | (D) ROOFING PRODUCTS AND ASSEMBLIES |
| | (G) PRE-ENGINEERED A/C STANDS |
| | |
| | 6)COMPLIED. DEFERRED SUBMITTAL.. 2010 FBC 107.3.4.1 |
| | PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE REGULATED |
| | BY THE DCA RULE 9N-03 SHALL BE REVIEWED AND APPROVED IN |
| | WRITING BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL |
| | FOR JURISDICTIONAL APPROVAL. FL 61G1-23.015 (2) THE |
| | ARCHITECT IS RESPONSIBLE FOR SUPERVISING AND REVIEWING |
| | ALL PROJECT DATA, REPORTS, SHOP DRAWINGS ETC.. |
| | |
| | EITHER THE DESIGNER OF RECORD OR CONTRACTOR CAN DEFER |
| | THE PRODUCT APPROVALS TO BE SUBMITTED AFTER PERMIT |
| | ISSUANCE AS A DEFERRED SUBMITTAL AS LONG AS THE |
| | PRESSURES ON THE BUILDING ARE CORRECT PLEASE REQUEST IN |
| | WRITING AS PART OF THE PERMIT DOCUMENTS. 107.3.4.2 |
| | DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS SECTION, |
| | DEFERRED SUBMITTALS ARE DEFINED AS THOSE PORTIONS OF |
| | THE DESIGN THAT ARE NOT SUBMITTED AT THE TIME OF THE |
| | APPLICATION AND THAT ARE TO BE SUBMITTED TO THE |
| | BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. DEFERRAL |
| | OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR APPROVAL OF |
| | THE BUILDING OFFICIAL. THE |
| | REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE |
| | SHALL LIST THE DEFERRED SUBMITTALS ON THE CONSTRUCTION |
| | DOCUMENTS FOR REVIEW BY THE BUILDING OFFICIAL. |
| | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE |
| | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN |
| | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD |
| | THEM TO THE BUILDING OFFICIAL WITH A NOTATION |
| | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE |
| | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO |
| | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL |
| | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED |
| | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING |
| | OFFICIAL. |
| | |
| | 7)2ND REQUEST. PLEASE NOTE THAT WELDED AND BOLTED |
| | CONNECTIONS WILL REQUIRE EITHER THIRD PARTY |
| | CERTIFICATION OR A RESIDENT INSPECTOR. PLEASE PROVIDE |
| | WHICH THE DESIGNER OF RECORD OR THE CONTRACTOR WISHES |
| | TO USE ON THIS PROJECT. IF A RESIDENT INSPECTOR IS |
| | CHOSEN, FORMS WILL BE E-MAILED FOR THE REQUIRED |
| | SIGNATURES BY ALL INVOLVED PARTIES. 110.3.9 OTHER |
| | INSPECTIONS SERVICES. |
| | |
| | 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING |
| | CODE, CHAPTER 1, ADMINISTRATION, 110.3.9 OTHER |
| | INSPECTIONS SERVICES. THE BUILDING OFFICIAL MAY MAKE, |
| | OR CAUSE TO BE MADE BY OTHERS, THE INSPECTIONS REQUIRED |
| | BY SECTION 109. HE/SHE MAY ACCEPT REPORTS OF INSPECTORS |
| | OF RECOGNIZED INSPECTION SERVICES, PROVIDED THAT AFTER |
| | INVESTIGATION HE/SHE IS SATISFIED AS TO THEIR |
| | QUALIFICATIONS AND RELIABILITY. A CERTIFICATE CALLED |
| | FOR BY ANY PROVISION OF THE TECHNICAL CODES SHALL NOT |
| | BE BASED ON SUCH REPORTS UNLESS THE SAME ARE IN WRITING |
| | AND CERTIFIED BY A RESPONSIBLE OFFICER OF SUCH SERVICE. |
| | THE BUILDING OFFICIAL MAY REQUIRE THE OWNER TO EMPLOY |
| | AN INSPECTION SERVICE IN THE FOLLOWING INSTANCES: |
| | |
| | 1. FOR BUILDINGS OR ADDITIONS OF TYPE I OR II |
| | CONSTRUCTION |
| | 2. FOR ALL MAJOR STRUCTURAL ALTERATIONS |
| | 3. WHERE THE CONCRETE DESIGN IS BASED ON COMPRESSIVE |
| | STRENGTH (F ?C) IN EXCESS OF 3000 |
| | POUNDS PER SQUARE INCH |
| | 4. FOR PILE DRIVING |
| | 5. FOR BUILDINGS WITH AREA GREATER THAN 20,000 SQUARE |
| | FOOT |
| | 6. FOR BUILDINGS MORE THAN 2 STORIES IN HEIGHT |
| | 7. FOR BUILDINGS AND STRUCTURES OF UNUSUAL DESIGN OR |
| | METHODS OF CONSTRUCTION |
| | |
| | 7A) RESIDENT INSPECTOR FORMS MUST BE SIGNED BY ALL |
| | PARTIES NOTARIZED AND RETURNED TO THE BUILDING |
| | DEPARTMENT. |
| | |
| | 7B) FOR THE RESIDENT INSPECTOR PLEASE PROVIDE A RESUME' |
| | OF INSPECTION EXPERIENCE ON PREVIOUS PROJECT. THE |
| | RESUME' MUST BE ACCOMPANIED BY ALL CERTIFICATES AS |
| | SPECIFIED HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE |
| | WILL REVIEW THE RESUME'. AFTER THE RESUME' IS REVIEWED, |
| | AN INTERVIEW WILL BE SCHEDULED. UNDER NO CIRCUMSTANCES |
| | WILL AN INSPECTOR BE INTERVIEWED FOR WORK WITHOUT FIRST |
| | MEETING THE ABOVE CRITERIA. |
| | CONTACT: KEN CONRAD |
| | TEL: 561-805-6666 |
| | E-MAIL: [email protected] |
| | |
| | 7C) THE CONTRACTOR WILL PRODUCE A JOB SUMMARY OR |
| | HISTORY FOR THIS TYPE OF CONSTRUCTION. THIS MAY BE |
| | SUBMITTED TO KEN CONRAD BY E-MAIL. KEN CONRAD: |
| | [email protected] |
| | |
| | 7D) NOTE FOR PAPER PLANS 3 SETS OF DOCUMENTS ARE |
| | REQUIRED. FOR DIGITAL PLANS, AFTER PERMIT ISSUANCE, THE |
| | PERMIT LIBRARIAN WILL E-MAIL YOU, THE APPROVED AND |
| | BATCH STAMPED PLANS SO YOU MAY PRINT YOUR PLANS, TWO |
| | SETS OF PLANS WILL NEED TO BE PRINTED IN COLOR, (1) FOR |
| | THE RESIDENT INSPECTOR, THE OTHER FOR THE MEP |
| | INSPECTORS. |
| | |
| | 7E) PLEASE CALL THE CITY OF WEST PALM BEACH?S AUTOMATED |
| | TELEPHONE INSPECTIONS LINE (561) 805-6700) FOR |
| | IN-PROGRESS INSPECTIONS FOR AUDITING OF JOBSITE |
| | INSPECTIONS. |
| | |
| | 8) COMPLIED. SHEET S5.1 DETAIL 8 PROVIDES THE |
| | ATTACHMENT OF THE CURB, WOOD BLOCKING MEMBERS AND TO |
| | THE STEEL FRAMING MEMBERS. THE MECHANICAL SHEET M1.2 |
| | SHOWS A FEW DETAILS OF ROOF TOP CURBS FOR THE NEW RTU'S |
| | ON THE ROOF BUT THERE IS NO ANCHORING DETAIL FOR THE |
| | CURBS, THE STRUCTURAL SHEETS DO NOT HAVE ANY ANCHORING |
| | DETAILS FOR THE ROOF TOP CURBS. COMPONENTS AND CLADDING |
| | ROOF TOP CURBS 1609.1.2. |
| | |
| | 9) 2ND REQUEST. SEMI-COMPLIED. THERE IS A DIFFERENCE IN |
| | HOW THE RTU UNIT IS TO BE ATTACHED BETWEEN SHEET A2.0 |
| | DETAIL # 1 AND SHEET S5.1 DETAIL # 8 THEY DO NOT MATCH |
| | UP. 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED. THE |
| | MECHANICAL NOR STRUCTURAL PLANS PROVIDE THE ATTACHMENT |
| | OF THE RTU TO THE CURB. PLEASE SHOW COMPLIANCE WITH |
| | COMPONENTS & CLADDING 1609.1.2. |
| | |
| | 10) COMPLIED. SHEET S1.1 SHOWS THE EXISTING AND NEW |
| | LAYOUT FOR NEW RTU'S ON THE ROOF. NEITHER THE A OR S |
| | PLANS INDICATE HOW COMPLIANCE WITH 2014 FBC-B SECTION |
| | 1509.6.4 EQUIPMENT AND APPLIANCES ON ROOFS OR ELEVATED |
| | STRUCTURES. WHERE EQUIPMENT AND APPLIANCES REQUIRING |
| | ACCESS ARE INSTALLED ON ROOFS OR ELEVATED STRUCTURES AT |
| | A HEIGHT EXCEEDING 16 FEET (4877 MM), SUCH ACCESS SHALL |
| | BE PROVIDED BY A PERMANENT APPROVED MEANS OF ACCESS, |
| | THE EXTENT OF WHICH SHALL BE FROM GRADE OR FLOOR LEVEL |
| | TO THE EQUIPMENT AND APPLIANCES? LEVEL SERVICE SPACE. |
| | SUCH ACCESS SHALL NOT REQUIRE CLIMBING OVER |
| | OBSTRUCTIONS GREATER THAN 30 INCHES (762 MM) HIGH OR |
| | WALKING ON ROOFS HAVING A SLOPE GREATER THAN 4 UNITS |
| | VERTICAL IN 12 UNITS HORIZONTAL (33-PERCENT SLOPE). |
| | PERMANENT LADDERS INSTALLED TO PROVIDE THE REQUIRED |
| | ACCESS SHALL COMPLY WITH THE FOLLOWING MINIMUM DESIGN |
| | CRITERIA: |
| | 10.1. THE SIDE RAILING SHALL EXTEND ABOVE THE PARAPET |
| | OR ROOF EDGE NOT LESS THAN 30 INCHES (762 MM). |
| | 10.2. LADDERS SHALL HAVE RUNG SPACING NOT TO EXCEED 14 |
| | INCHES (356 MM) ON CENTER. |
| | 10.3. LADDERS SHALL HAVE A TOE SPACING NOT LESS THAN |
| | 6-INCHES (152 MM) DEEP. |
| | 10.4. THERE SHALL BE A MINIMUM OF 18 INCHES (457 MM) |
| | BETWEEN RAILS. |
| | 10.5. RUNGS SHALL HAVE A MINIMUM 0.75-INCH (19 MM) |
| | DIAMETER AND BE CAPABLE OF WITHSTANDING A 300-POUND |
| | (136.1 KG) LOAD. |
| | 10.6. LADDERS OVER 30 FEET (9144 MM) IN HEIGHT SHALL BE |
| | PROVIDED WITH OFFSET SECTIONS AND LANDINGS CAPABLE OF |
| | WITHSTANDING 100 POUNDS PER SQUARE FOOT (488.2 KG/M2). |
| | 10.7. LADDERS SHALL BE PROTECTED AGAINST CORROSION BY |
| | APPROVED MEANS. CATWALKS INSTALLED TO PROVIDE THE |
| | REQUIRED ACCESS SHALL BE NOT LESS THAN 24-INCHES (610 |
| | MM) WIDE AND SHALL HAVE RAILINGS AS REQUIRED FOR |
| | SERVICE PLATFORMS. |
| | |
| | 11) COMPLIED. ZONING COMMENTS INDICATE THERE MAY HAVE A |
| | NEED TO SCREEN THE MECHANICAL EQUIPMENT ON THE ROOF. |
| | PLEASE SHOW COMPLIANCE WITH? 1509.6.1 HEIGHT |
| | LIMITATIONS. |
| | MECHANICAL EQUIPMENT SCREENS SHALL NOT EXCEED 18 FEET |
| | (5486 MM) IN HEIGHT ABOVE THE ROOF DECK, AS MEASURED TO |
| | THE HIGHEST POINT ON THE MECHANICAL EQUIPMENT SCREEN. |
| | PLEASE PROVIDE THE ATTACHMENT FOR SCREEN FRAMING AS |
| | WELL AS THE SCREEN MATERIAL ITSELF, SHOW COMPLIANCE |
| | WITH 1609.6 WIND DESIGN. |
| | |
| | 12) WHEN RESUBMITTING PLANS PLEASE INDICATE THE |
| | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES |
| | AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |
| | |
| | |
| | |