| Date |
Text |
| 2015-09-04 13:43:49 | BUILDING PLAN REVIEW |
| | W. P. B. PERMIT:15090175 |
| | ADD:3012 EMBASSY DR. |
| | CONT: BOWERS ROOFING |
| | TEL: (954)418-4390 |
| | E-MAIL: ??????????? |
| | |
| | 2014 FLORIDA BUILDING CODE W * 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION, |
| | |
| | 1ST REVIEW |
| | DATE: FRI. SEPT. 04/2015 |
| | ACTION: DENIED |
| | |
| | 1) THE PERMIT APPLICATION INDICATES UNDER THE |
| | DESCRIPTION OF WORK: ROOF REPAIR. THE SQUARE FOOT AREA |
| | OF ROOF REPAIRS IS APPROXIMATELY 1914 SQ. FT. THE |
| | OVERALL SQUARE FOOTAGE OF THE SLOPED ROOF IS |
| | APPROXIMATELY 3851 SQ. FT. THE AREA OF REPAIR IS 50% OF |
| | THE OVERALL ROOF SQUARE FOOTAGE. |
| | THE 2014 FBC-EXISTING BUILDING CODE SECTION 708.1.1 |
| | LIMITS THE REPAIR OF THE ROOF TO NOT MORE THAN 25 % OF |
| | THE TOTAL ROOF OR ROOF SECTION. |
| | |
| | 2014 FBC-EXISITNG BUILDING CODE 708.1.1 |
| | NOT MORE THAN 25 PERCENT OF THE TOTAL ROOF AREA OR ROOF |
| | SECTION OF ANY EXISTING BUILDING OR STRUCTURE SHALL BE |
| | REPAIRED, REPLACED OR RECOVERED IN ANY 12-MONTH PERIOD |
| | UNLESS THE ENTIRE ROOFING SYSTEM OR ROOF SECTION |
| | CONFORMS TO REQUIREMENTS OF THIS CODE. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | DEVELOPMENT SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| | |
| | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| | |
| | |
| | |