2015-10-20 14:41:591ST REVIEW: FBC 2014 5TH ED.
  
 UPDATE THE PLAN TO INDICATE COMPLIANCE WITH THE
 FOLLOWING:
  
 FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE IMPACT RESISTANT SKYLIGHT
 SUBMITTAL.
  
 FBC-R310.1 EMERGENCY ESCAPE AND RESCUE REQUIRED IN
 BEDROOM 2 AS FOLLOWS: WHERE EMERGENCY ESCAPE AND RESCUE
 OPENINGS ARE PROVIDED THEY SHALL HAVE A SILL HEIGHT OF
 NOT MORE THAN 44 INCHES (1118 MM) MEASURED FROM THE
 FINISHED FLOOR TO THE BOTTOM OF THE CLEAR OPENING.
 R310.1.1 MINIMUM OPENING AREA GRADE FLOOR OPENINGS
 SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5 SQUARE FEET
 R310.1.2 MINIMUM OPENING HEIGHT.
 THE MINIMUM NET CLEAR OPENING HEIGHT SHALL BE 24 INCHES
 R310.1.3 MINIMUM OPENING WIDTH.
 THE MINIMUM NET CLEAR OPENING WIDTH SHALL BE 20 INCHES
  
 FBC-R 315.1 ? PROVIDE CARBON MONOXIDE ALARMS WITHIN 10
 FEET OF EACH SLEEPING ROOM.
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER