| Plan Review Notes For Permit 15081084 |
| Permit Number |
15081084 |
|
| Review Stop |
FIRE |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2015-08-31 14:37:55 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | 1) SHEET C 3, THE EXTERIOR STAIR RAILING HEIGHT | | | INDICATED IS NOT CODE COMPLIANT WITH NFPA CHAPTER 7, | | | 7.2.2.4 GUARDS AND HANDRAILS. NEW HANDRAILS ON STAIRS | | | SHALL NOT BE LESS THAN 34 IN. AND NOT MORE THAN 38 IN. | | | ABOVE THE SURFACE OF THE TREAD, MEASURED VERTICALLY TO | | | THE TOP OF THE RAIL FROM THE LEADING EDGE OF THE TREAD. | | | | | | 2) SHEET S 3, THE INTERIOR STAIR AND HABDRAIL SHALL | | | COMPLY WITH NFPA CHAPTER 7 AND # 1 ABOVE. | | | |
|