Plan Review Notes
Plan Review Notes For Permit 15081084
Permit Number 15081084
Review Stop FIRE
Sequence Number 1
Notes
Date Text
2015-08-31 14:37:55THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 1) SHEET C 3, THE EXTERIOR STAIR RAILING HEIGHT
 INDICATED IS NOT CODE COMPLIANT WITH NFPA CHAPTER 7,
 7.2.2.4 GUARDS AND HANDRAILS. NEW HANDRAILS ON STAIRS
 SHALL NOT BE LESS THAN 34 IN. AND NOT MORE THAN 38 IN.
 ABOVE THE SURFACE OF THE TREAD, MEASURED VERTICALLY TO
 THE TOP OF THE RAIL FROM THE LEADING EDGE OF THE TREAD.
  
 2) SHEET S 3, THE INTERIOR STAIR AND HABDRAIL SHALL
 COMPLY WITH NFPA CHAPTER 7 AND # 1 ABOVE.
  