| 2015-08-24 14:37:21 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL |
| | BUILDING PLANS EXAMINER |
| | [email protected] |
| | 561-805-6724 |
| | |
| | 1. THERE ARE TWO STRUCTURES ON THIS PARCEL. PROVIDE A |
| | SITE PLAN WHICH SHOWS WHICH STRUCTURE IS TO BE INCLUDED |
| | IN THIS REROOF PERMIT, FBC 107. |
| | |
| | 2. PROVIDE A ROOF PLAN SHOWING DIMENSIONS, LOCATION OF |
| | THE ROOF INCLUDED IN THIS REROOF PERMIT. SCOPE NOT |
| | CLEAR, FBC 107. |
| | |
| | 3. TWO DIFFERENT PRODUCT APPROVALS WERE PROVIDED. ONLY |
| | ONE PRODUCT APPROVAL SHOULD BE PROVIDED. |
| | |
| | IF USING THE MIAMI DADE NOA, INDICATE WHICH APPROVED |
| | ASSEMBLY IS PROPOSED AND PROVIDE ENGINEERING IF |
| | REQUIRED (SEE GENERAL LIMITATION #7 ON THE LAST PAGE OF |
| | THE NOA). |
| | |
| | IF USING A FLORIDA STATE PRODUCT APPROVAL, PROVIDE ALL |
| | SHEETS WHICH PERTAIN TO THE PRODUCT AND ASSEMBLY |
| | SELECTED. THE COVER PAGE (SHOWS CODE VERSION AND |
| | STATUS, WWW.FLORIDABUILDING.ORG), EVALUATION |
| | REPORT/INSTALLATION INSTRUCTIONS (INCLUDE PAGES WHICH |
| | APPLY TO ALL ASSEMBLIES AS WELL AS THE ASSEMBLY |
| | SELECTED). ONLY THE ASSEMBLY WAS PROVIDED. IF YOU ARE |
| | NOT SURE WHICH SHEETS TO EXCLUDE, PROVIDE ALL PAGES AND |
| | THE UNNECESSARY SHEETS (PAGES SPECIFIC TO AN ASSEMBLY |
| | NOT PROPOSED UNDER THIS PERMIT) WILL BE REMOVED. |
| | |
| | IT APPEARS THAT CONTRACTOR IS ATTEMPTING TO USE |
| | ENHANCED FASTENING IN THE FLORIDA APPROVAL FOR A MIAMI |
| | DADE NOA. THIS IS NOT ACCEPTABLE; SELECT ONE PRODUCT |
| | APPROVAL AND FOLLOW THE GUIDELINES OF THAT APPROVAL. |
| | |
| | FBC 5TH EDITION RESIDENTIAL 301 |
| | |