| Date |
Text |
| 2015-11-05 08:32:21 | BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 15080784 |
| | ADD: 330 CLEMATIS STREET # 110 |
| | CONT: TBD |
| | TEL: (561)686-5853 |
| | E-MAIL: [email protected] |
| | |
| | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION, |
| | |
| | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| | FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 2ND REVIEW |
| | DATE: THURS. NOV. 11/2015 |
| | ACTION: BUILDING PROVISO |
| | |
| | 1) DOOR NUMBER # 7 NEEDS TO BE REVERSED TO A OUTSWING |
| | DOOR, FOR COMPLIANCE WITH 2014 FBC-ACCESSIBLITY CODE |
| | 404.2.4.1 MANEUVERING CLEARANCES, 18 INCHES ON THE |
| | LATCH SIDE OF THE DOOR. |
| | |
| | 2) PLEASE PROVIDE COMPLIANCE WITH THE BAR AREA IN THE |
| | EXTERIOR WALL. SHOW HOW COMPLIANCE WITH 2014 |
| | ACCESSIBILITY CODE 226.2 DISPERSION.DINING SURFACES |
| | REQUIRED TO COMPLY WITH 902 SHALL BE DISPERSED |
| | THROUGHOUT THE SPACE OR FACILITY CONTAINING DINING |
| | SURFACES. |
| | 2014 FBC-ACCESSIBILITY CODE 902.3 HEIGHT, PLEASE SHOW |
| | HOW COMPLIANCE WITH THE HEIGHT OF THE BAR WILL BE |
| | ACHIEVED. THE TOP OF DINING SURFACES SHALL BE A MINIMUM |
| | OF 28 INCHES AND A MAXIMUM OF 34 INCHES ABOVE THE |
| | FINISH FLOOR. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | DEVELOPMENT SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |