| 2015-08-25 18:45:04 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. REVISE PLAN TO SHOW FIRE RATED WALLS AS WELL AS FIRE | | | RATING, FBC 107, FBC 715.4. | | | | | | 2. REVISE PLAN TO INCLUDE THE NUMBER OF STORIES IN THIS | | | BUILDING. THREE FLOORS ARE SHOWN ON THE PLAN, BUT | | | AERIAL PHOTOGRAPHY APPEARS TO SHOW A FIVE STORY | | | BUILDING. A 2 HOUR STAIR EXIT ENCLOSURE IS REQUIRED FOR | | | A FIVE STORY BUILDING, 90 MINUTE DOORS REQUIRED, FBC | | | TABLE 719.4. | | | | | | REVISE PLAN TO CLARIFY AND SHOW COMPLIANCE. | | | | | | 3. FOR OUR RECORDS, PROVIDE A COPY OF THE ASBESTOS | | | REMOVAL PERMIT. | | | | | | 4. FIRE PLAN REVIEW BY STATE FIRE MARSHALL REQUIRED. | | | | | | | | | | | | | | | |
|