| 2015-08-26 07:21:51 | |
| | BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 15080547 |
| | ADD: 550 S. ROSEMARY AVE. #160 |
| | CONT: DC GREEN, LLC |
| | TEL: (772)919-1412 |
| | E-MAIL: [email protected] |
| | |
| | 2014 FLORIDA BUILDING CODE W * 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION, |
| | |
| | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| | FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: WED. AUGUST 26/2015 |
| | ACTION: DENIED |
| | |
| | 1) PLANS WERE NOT STAMPED REVIEWED BY CITY PLACE |
| | MANAGEMENT THEY WERE REVIEWED AND APPROVED. 107.2.1.3 |
| | ADDITIONAL INFORMATION IS REQUIRED. |
| | |
| | 2) THERE IS NO DEMOLISION PLANS INDICATING WHAT IS |
| | BEING DEMOED OR CHANGED, IS EVERYTHING TO BE CONSIDERED |
| | NEW? 107.3.5.1.1 MINIMUM PLAN REVIEW CRITERIA FOR |
| | COMMERCIAL BUILDINGS. FROM THE LAST KNOWN PERMIT |
| | 13010420 THERE IS ALOT OF INTERIOR CHANGES FROM THE |
| | LAST KNOWN USE AS FAR AS LAY OUT AND LIFE SAFETY PLAN. |
| | A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A |
| | RESULT OF THE ADDITIONAL INFORMATION REQUESTED |
| | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF |
| | THIS REVIEW. |
| | |
| | 3) FOR THE AMOUNT OF CHANGES SEEN FROM THE LAST PERMIT |
| | (13010420) AND THE PROPOSED LAYOUT THE PERMIT VALUE |
| | ASSOCIATED WITH THIS DESIGN IS CONSIDERABLY |
| | LOW,EXTREMELY LOW. PERMIT FEES/ PLAN REVIEW: |
| | W P B ADMINISTRATIVE CODE 108.2 SCHEDULE OF PERMIT |
| | FEES. ON BUILDINGS, STRUCTURES, ELECTRICAL, GAS, |
| | MECHANICAL AND PLUMBING SYSTEMS OR ALTERATIONS |
| | REQUIRING A PERMIT, A FEE FOR EACH PERMIT SHALL BE PAID |
| | AS REQUIRED, IN ACCORDANCE WITH THE SCHEDULE |
| | ESTABLISHED BY THE APPLICABLE GOVERNING AUTHORITY. |
| | |
| | 108.3* BUILDING PERMIT VALUATION. |
| | IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE |
| | CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE, |
| | ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS |
| | APPEARS TO BE UNDER ESTIMATED ON THE APPLICATION, THE |
| | PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES, |
| | VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL |
| | REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND |
| | SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE |
| | STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR |
| | FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR |
| | BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING |
| | COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. |
| | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED |
| | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES |
| | (MARSHALL-SWIFT, MEANS, ETC.) WITH REGIONAL ADJUSTMENTS |
| | FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE |
| | CONGRESS. |
| | |
| | 4) SHEET A120.1THE MENS RESTROOM APPEARS TO HAVE BEEN |
| | RENOVATED WITH THE ADDITION OF A NEW LAV. THE ENTRY |
| | WALL HAS BEEN MOVED WITH THE ENTRY DOOR IN CONFLICT |
| | WITH THE UNISEX TOLIET ROOM NOT THE EXISTING STAFF |
| | RESTROOM. NOTE THE UNISEX TOLIET ROOM CAN HAVE A |
| | INSWING DOOR SO IT DOESN'T BLOCK THE MENS RESTROOM |
| | DOOR. |
| | 2014 FBC-ACCESSIBILITY CODE 603.2.3 EXCEP. # 2. DOOR |
| | SWING. |
| | 2014 FBC-P 403.5 UNISEX RESTROOMS SEE PLUMBING |
| | COMMENTS. |
| | |
| | 5) SHEET A120.1 EXISTING BEER COOLER 121 HAS BEEN |
| | EXSPANDED THERE WAS A HALL 111 THAT LEAD TO THE BACK OF |
| | HOUSE EXIT PASSAGEWAY WITH RATED DOOR. THIS DOOR HAS |
| | BEEN ELIMINATED, THE PLANS DO NOT SHOW HOW THE FIRE |
| | RATING OF THE EXIT PASSAGEWAY WAS MAINTAINED. 2014 |
| | FBC-B 1023.3. |
| | |
| | 6) SHEET A120.1 LUMINARIES LOUNGE SHOWS A RAISED |
| | PLATFORM, UNDER PERMIT 13010420 THIS WAS A STAGE, IT |
| | APPEARS THERE IS NEW KNEE WALLS AND WHAT APPEARS TO BE |
| | STEPS. PLEASE PROVIDE AT WHAT ELEVATION THE PLATFORM IS |
| | ABOVE FINISH FLOOR. 107.2.1.3 ADDITIONAL INFORMATION IS |
| | REQUIRED. |
| | |
| | 6A) SHEET A120.1 THE PROPOSED PLANS SHOW WORK ON THE |
| | EAST AND SOUTH OUTSIDE DINING AREA WITH WALLS MOVED, |
| | DOORS OPENINGS BEING MODIFIED, A NEW OUTSIDE LOUNGE |
| | AREA WALLS REMOVED, THE KITCHEN NEW COOLERS, OLD ONES |
| | MOVED BAR LOCATIONS AND WALLS MOVED ETC.... |
| | |
| | 7) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A |
| | RESULT OF THE ADDITIONAL INFORMATION REQUESTED |
| | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF |
| | THIS REVIEW. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |