| Date |
Text |
| 2016-01-05 08:12:52 | BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 15080531 |
| | ADD: 8989 OKEECHOBEE BLVD./ PUBLIX |
| | CONT: HAWKINS |
| | TEL: ( 561)314-6730 |
| | E-MAIL: ????????????? |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 2ND REVIEW |
| | DATE: TUES. JAN. 05/ 2016 |
| | ACTION: DENIED |
| | |
| | 1A) 2ND REQUEST. SHEET SP-1 (SEE DETAIL E 5/SP1)SHOWS |
| | (2) HANDICAPPED PARKING SPACES NEXT TO EACH OTHER WITH |
| | (2) SEPARATE ACCESS AISLES, NOTE THERE IS NO CENTRAL |
| | ACCESS AISLE BETWEEN THE ROWS OF CARS TO ALLOW AN |
| | OCCUPANT TO TRAVEL IN THE FRONT OF A CAR RATHER THAN |
| | BEHIND ANOTHER PARKED CAR. THIS TYPE OF CONFIGURATION |
| | HAPPENS TWICE ON THE PLANS DATED 05/07/15. |
| | NOTE THIS IS ALLOWED WHEN THE OCCUPANT OF NEITHER SPACE |
| | IS COMPELLED TO WALK OR WHEEL BEHIND PARKED VEHICLES, |
| | EXCEPT BEHIND THEIR OWN VEHICLE. SEE 2014 FL ACCESSIBLE |
| | CODE 208.3.1. |
| | |
| | 1B)COMPLIED. LETTER. ACCESSIBILITY CODE |
| | DISPROPORTIONATE COST 20 %. |
| | |
| | 2)COMPLIED. THE 2014 FBC, 5TH EDITION WAS ADOPTED |
| | STATEWIDE ON JUNE 30TH/ 2015. |
| | |
| | 3)SEMI-COMPLIED. THE STRUCTURAL SHEET S-2 INDICATES |
| | THEY WERE DESIGNED TO THE 2010 FBC. PLANS WERE |
| | SUBMITTED ON AUGUST 14/ 2015 UNDER THE 2014 FBC-B |
| | UPDATE PLANS. |
| | |
| | THIS PORTION WAS COMPLIED. THEY ALSO INDICATE THEY ARE |
| | DESIGNED UNDER THE HIGH WIND VELOCITY ZONE- MIAMI-DADE |
| | COUNTY VULT 175. PLEASE NOTE THE DESIGNER CAN DESIGN TO |
| | A MORE STRINGENT STANDARD BUT THE PRESSURES FOR THE |
| | HIGHER STANDARD WILL ALSO BE APPLICABLE. |
| | |
| | 4) COMPLIED, ROOF ACCESS |
| | |
| | |
| | 5) COMPLIED 2014 FBC-B 1509.6.5 MECHANICAL UNITS. FBC-B |
| | TABLE 1509.6.5. |
| | |
| | 6) COMPLIED. 20104 FBC-B 1509.6 MECHANICAL EQUIPMENT |
| | SCREENS EXISTING PARAPETS. |
| | |
| | 7) SEMI-COMPLIED. S-2 INDICATES NEW AND EXISTING |
| | ROOFTOP CURBS WITH CURB ADAPTORS PLEASE PROVIDE |
| | COMPLIANCE WITH 2014 FBC-B 1609.1.2 PROTECTION OF |
| | OPENINGS, 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA |
| | DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 |
| | (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS |
| | THAT WILL REQUIRE PRODUCT APPROVALS: |
| | COMPLIED. (31) (D) ROOFING PRODUCTS AND ASSEMBLIES/ |
| | CURBS/ ADAPTORS |
| | |
| | THE RESPONSE LETTER INDICATES TO SEE THE ATTACHED |
| | CALCULATIONS. THE ISSUES WITH CALCULATIONS, STRUCTURAL |
| | CALCULATIONS BY DOUGLAS RAMIREZ FOR 8989 OKEECHOBEE |
| | BLVD. PUBLIX SUPERMARKETS REFERENCES ASCE 7-10 WITH THE |
| | 170 MPH AND ALSO THE 2010 FBC. THE PLANS WERE SUBMITTED |
| | UNDER THE 2014 FBC, ASCE 7-10, 170 MPH. UNDER THE 2010 |
| | FBC THE WIND SPEED WAS 140 MPH (VASD) A STRONGER CODE |
| | THAN THE CURRENT CODE. |
| | |
| | 8) COMPLIED, NO NEW PRE-MANUFACTURED A/C STANDS. |
| | |
| | 9) PLEASE NOTE ANY ROOF FRAMING, ROOF DECKING THAT WILL |
| | REQUIRE WELDING AND OR BOLTED CONNECTIONS WILL REQUIRE |
| | A (3RD PARTY CERTIFICATION) CONTACT KEN CONRAD MANAGER |
| | OF SPECIAL INSPECTOR/ RESIDENT INSPECTOR PROGRAM. TEL: |
| | 561-805-6666. NOTE ONLY 3RD PARTY CERTIFICATION IS |
| | REQUIRED, NOT A ONSITE RESIDENT INSPECTOR OR SPECIAL |
| | INSPECTOR. |
| | |
| | 10) WHEN RESUBMITTING PLANS PLEASE INDICATE THE |
| | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES |
| | AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |