2016-02-23 07:44:39BUILDING PLAN REVIEW
 W. P. B. PERMIT:15080289
 ADD: 1001 OKEECHOBEE BLVD
 CONT: C & I CONSTRUCTION & DESIGN
 TEL: (305)255-6067
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W * 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION,
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 4TH REVIEW
 DATE: TUES. FEB. 23 / 2016
 ACTION: DENIED
  
 NOTICE!!!!!!!!!!!!! CHAPTER 553.80(2)(B) FLORIDA
 STATUTES STATES THAT A LOCAL GOVERNMENT SHALL IMPOSE A
 FEE OF FOUR TIMES THE FEE FOR PLAN REVIEW, IF PLANS ARE
 REJECTED (3) OR MORE TIMES FOR REPEATED FAILURE TO
 CORRECT A CODE VIOLATION.
  
 1-2) COMPLIED. ASTM F2200-05 SCOPE 1.4 AUTOMATED
 VEHICULAR GATES THAT DO NOT COMPLY WITH THIS
 SPECIFICATION SHALL BE SUBJECT TO INDEPENDENT
 EVALUATION FOR COMPLIANCE WITH UL 325.
  
  
  
 3) 4TH REQUEST. THE AMG-1752 FROM UL HAS NOTHING TO DO
 WITH THE WIND DESIGN FOR THE STRUCTURE (STAND) AND ITS
 ATTACHMENT TO THE STRUCTURAL CONCRETE BASE. THE
 BUILDING & SSTRUCTURES CLASSIFIED AS A CATEGORY I
 STRUCTURE INCLUDES FARM OUT BUILDINGS (SHEDS) STREET
 POLES, STOP SIGNS, WALL SIGNS, MONUMENT SIGNS,
 STRUCTURES THAT ARE NOT HABITABLE...
 THIS IS WHERE WE ARE LOOKING FOR A DETAIL SHOWING THE
 ATTACHMENT OF THE STAND BASE TO THE FOUNDATION WILL
 WITHSTAND THE 160 VULT MPH WINDS. THESE CALCULATIONS
 ARE USUALLY COMPLETED BY A ENGINEER OF RECORD. THE
 CALCULATIONS SHOULD ALSO INDICATE IF THEY WERE
 COMPLETED WITH THE GATE ARM REMOVED FOR HIGH WIND
 EVENTS OR NOT!!!!
 THERE IS NO WIND DESIGN CRITERIA NOR HOW THIS EQUIPMENT
 WILL BE ANCHORED TO WITHSTAND THE MOMENT OF OVER
 TURNING FOR THIS WIND BORN DEBRIS REGION? BUILDING
 CATEGORY I WIND ZONE 160 MPH VULT. 3 SECOND GUST
  
 2014 FBC-B 1609.1.1 DETERMINATION OF WIND DESIGN-
 CHAPTER 6 OF ASCE 7-10.
 1609.3 BASIC WIND SPEED FIGURE 1609.A-C
 1609.3 WIND SPEED CONVERSION
 3.1) THE BASIC WIND SPEED, VU, SHALL BE DETERMINED IN
 ACCORDANCE WITH 1609.3.1 & ASCE 7-10
  
 3.2) AN IMPORTANCE FACTOR, FIGURE 1609 A-C, ASCE 7-10.
  
 3.3) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN
 ACCORDANCE WITH 1609.4 & ASCE 7-10
  
 3.4) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, *
 SHALL BE DETERMINED FROM TABLE 1609.7.2. ASCE 7-10.
  
 3.5) COMPONENTS & CLADDING PRESSURES POSITIVE &
 NEGATIVE TABLE 1609.2(2) .
  
 4) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  