| Date |
Text |
| 2015-09-28 10:28:54 | PLAN |
| | REVIEW COMMENTS |
| | |
| | 1ST REVIEW: FBC FIFTH EDITION (2014) |
| | ROBERT MCDOUGAL, CBO |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | (561) 805-6714 |
| | [email protected] |
| | |
| | DENIED BY BUILDING |
| | PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| | |
| | 1) SUBMIT TWO SETS OF RESIDENTIAL BUILDING FORMS TO |
| | SHOW COMPLIANCE WITH 2014 FBC ENERGY CONSERVATION |
| | R101.5 |
| | |
| | 2) THE SIZES OF THE BEAMS SHOWN ON THE PLANS SUPPORTING |
| | THE SECOND FLOOR WALLS ARE DIFFERENT ON SHEETS A210 AND |
| | S-2. FBC 107.2.1 |
| | |
| | 3) ON SHEET S-3 THE MARKS FOR SECTIONS 1, 2, 3 AND 4 |
| | REFER TO SHEET S-2 AND THE SECTIONS ARE ON SHEET S-6. |
| | FBC 107.2.1 |
| | |
| | 4) SPECIFY THE REQUIRED COMPONENT AND CLADDING DESIGN |
| | PRESSURES FOR THE EXTERIOR DOORS AND WINDOWS ON THE |
| | PLANS. FBC - R301.2.1 |
| | |
| | 5) SUBMIT TWO COPIES OF THE EVALUATION REPORTS WITH |
| | INSTALLATION INSTRUCTIONS FOR THE SPRAY FOAM |
| | INSULATION. FBC - R316 |
| | |
| | 6) SUBMIT TWO COPIES OF THE MANUFACTURER'S |
| | SPECIFICATIONS WITH INSTALLATION INSTRUCTIONS AND |
| | LISTING FOR THE IISOKERN FIREPLACE. FBC - R1001 & M1801 |
| | |
| | 7) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS |
| | FOR THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3 |
| | THAT HAVE BEEN REVIEWED AND APPROVED IN WRITING BY THE |
| | DESIGNER OF RECORD. PROVIDE TWO COMPLETE PRODUCT |
| | APPROVALS WITH FL OR NOA NUMBERS INCLUDING INSTALLATION |
| | INSTRUCTIONS AND MAXIMUM DESIGN PRESSURES FOR THE CLAY |
| | S-TILE ROOFING MATERIAL AND THE ARCH TOP FRONT DOOR. |
| | |
| | 8) SPECIFY THE SPECIFIC METHOD OF ATTACHMENT THAT WILL |
| | BE USED TO INSTALL THE CLAY S-TILE AND RESIST THE |
| | REQUIRED OVERTURN MOMENT. IF AN ADHESIVE IS USED SUBMIT |
| | THE PRODUCT APPROVALS FOR IT. FBC - R905.3 & DCA RULE |
| | 9N-3 |