| Date |
Text |
| 2015-10-16 11:46:39 | ROOFING PLAN REVIEW |
| | W. P. B. PERMIT:15080178 / NEW 7/11 BUILDING |
| | ADD: 2100 45TH ST. |
| | CONT: TBD/ TO BE DETERMINED |
| | TEL: (???)???-???? |
| | E-MAIL:???????????????? |
| | |
| | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION, |
| | |
| | 2ND REVIEW |
| | DATE: FRI. OCT. 16/ 2015 |
| | ACTION: DENIED |
| | |
| | 1) 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, |
| | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT |
| | OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) |
| | SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT |
| | WILL REQUIRE PRODUCT APPROVALS: |
| | (31)(D) ROOFING PRODUCTS AND ASSEMBLIES, CURBS |
| | (G) PRE-ENGINEERED A/C STANDS |
| | |
| | ROOFING PRODUCT APPROVAL SUBMITTED NOA 13-0419.05 PAGE |
| | 08 MAXIMUM DESIGN PRESSURE OF -45 AND LIMITATION NUMBER |
| | 9 NO ENHANCED FASTENING IS ALLOWED!!!!!!! |
| | |
| | SKYLIGHT REPORT PTC IS A OLD 2007 REPORT UNDER RULE 9B. |
| | PLEASE NOTE RULE 9B ENDED OCT 31/ 2010. RULE 9N-3 |
| | REPLACED THIS RULE NOV.01/2010. THERE HAS BEEN 2 CODE |
| | CYCLES THE 2010 AND 2014 FBC, PLEASE UPDATE EVALUATION |
| | REPORT. NOTE THE NOA 08-0305.02 POLYCARBONATE IS A |
| | EXPIRED REPORT ALSO. |
| | |
| | CARRIER ROOF TOP CURBS NOA 15-0218.11 PLEASE BE AWARE |
| | THERE IS A ISSUE WITH THE RESTRAINT BRACKET SHOWN ON |
| | SHEET 2 OF 5, ALSO SEE DETAIL OF RESTRAINT BRACKET ON |
| | SHEET 5 OF 5. SHEET 2 OF 5 INDICATES (7) # 10 TEK |
| | SCREWS THAT ARE TO HOLD THE RESTRAINT BRACKET TO THE |
| | ROOF CURB. PAGE 5 SHOWS THE BRACKET DOES NOT TURN DOWN |
| | THE INTERIOR OF THE CURB. HOW WILL THE RESTRAINT |
| | BRACKET BE HELD TO THE CURB. |
| | DISCREPANCY IN PLANS. 107.2.1.3. ADDITIONAL INFORMATION |
| | IS REQUIRED. |
| | |
| | NOA 14-0513.10 IS FOR THE ROOFTOP FANS, NO PRODUCT |
| | APPROVALS WAS SUBMITTED FOR THE CURB. HIGHLIGHT CIRCLE |
| | TYPE OF UNIT AND PRESSURES. 107.2.1.3 ADDITIONAL |
| | INFORMATION IS REQUIRED. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |