| Date |
Text |
| 2015-08-13 08:22:59 | BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 15080126 |
| | ADD: 333 CLEMATIS ST. SUITE # 100 |
| | CONT: HORMAK CONSTRUCTION |
| | TEL: (561)790-6863 |
| | E-MAIL: [email protected] |
| | |
| | 2014 FLORIDA BUILDING CODE W |
| | * 2014 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, |
| | |
| | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| | FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: THURS. AUG. 13/ 2015 |
| | ACTION: DENIED |
| | |
| | CHANGE IN OCCUPANCY FROM A MERCANILE TO BUSINESS. TO BE |
| | REVIEWED UNDER THE 2014 EXISITNG BUILDING CODE CHAPTER |
| | 10. |
| | |
| | 1) SHEET A1 UNDER THE HEADING APPLICABLE CODES MAKES |
| | REFERENCE TO THE 2010 FBC AND FAMILY OF CODES. PLEASE |
| | NOTE ON JUNE 30/ 2015 STATEWIDE THE 5TH EDITION OF THE |
| | FLORIDA BUILDING CODE (2014 FBC) WAS ADOPTED, PLEASE |
| | UPDATE PLANS. |
| | |
| | 2) PLEASE NOTE THE CONTRACT VALUE OF THIS PROJECT IS |
| | $20,000.00 DOLLORS. PLEASE PROVIDE A ITEMIZED LIST |
| | WHERE THESE FUNDS ARE TO BE SPENT. 2014 |
| | FBC-ACCESSIBILITY PLEASE REVIEW WHERE MONIES ARE TO BE |
| | SPENT IN THIS ORDER SEE 202.4.2 ACCESSIBLE FEATURES IN |
| | THE EVENT OF DISPROPORTIONALITY. |
| | |
| | 3) SHEET A1 SHOWS THE REAR EXTERIOR DOOR BEING BLOCKED |
| | IN. DOOR # 104 A EXISTING NON-CONFORMING DOOR WILL BE A |
| | REQUIRED MEANS OF EGRESS. |
| | THIS TENNANT SPACE IS APPROXIMATELY 120 FEET DEEP. THE |
| | 2014 FBC-B TABLE 1013.3 WITH AN OCCUPAN LOAD LESS THAN |
| | OR EQUALL TO 30 NON-SPRINKLERED BUILDING COMMON PATH OF |
| | TRAVEL IS LIMITED TO 100 FEET. THIS TENNANT SPACE WILL |
| | REQUIRE 2 MEANS OF EGRESS. |
| | |
| | 4) PLEASE REFER TO THE 2014 FBC-ACCESSIBILITY CODE TO |
| | 207.1. MEANS OF EGRESS SHALL COMPLY WITH SECTION |
| | 1003.2.13 OF THE INTERNATIONAL BUILDING CODE (2000 |
| | EDITION AND 2001 SUPPLEMENT) OR SECTION 1007 OF THE |
| | INTERNATIONAL BUILDING CODE (2003 EDITION) |
| | (INCORPORATED BY REFERENCE, SEE ?REFERENCED STANDARDS? |
| | IN CHAPTER 1). |
| | |
| | 2003 IBC0-B 1007.1 WHERE MORETHAN ONE OF MEANS OF |
| | EGRESS IS REQUIREDBY SECTION 1014.1 OR 1018.1 FROM ANY |
| | ACCESSIBLE SPACE,EACH ACCESSIBLE PORTIONOF THE SPACE |
| | SHALL BE SERVED BY NOT LESS THAN TWO ACCESSIBLE MEANS |
| | OF EGRESS. |
| | |
| | 2014 FBC-B- ACCESS.CODE (FL. SPECIFIC GRAY BOX) 207.1.1 |
| | BARRIERS AT COMMON OR EMERGENCY ENTRANCES AND EXITS OF |
| | BUSINESS ESTABLISHMENTS CONDUCTING BUSINESS WITH THE |
| | GENERAL PUBLIC THAT ARE EXISTING, UNDER CONSTRUCTION, |
| | OR UNDER CONTRACT FOR CONSTRUCTION WHICH WOULD PREVENT |
| | A PERSON FROM USING SUCH ENTRANCES OR EXITS SHALL BE |
| | REMOVED. |
| | |
| | 5) DISCREPANCY IN PLANS SHEET A1 VERSES A2. PLEASE |
| | REVIEW THE NEW EXTERIOR FRONT DOOR 101. SHEET A-1 |
| | INDICATES A SINGLE EXTERIOR SWING DOOR WHERE AS SHEET |
| | A2 INDICATES THIS SAME DOOR 101 TO BE A (2) 3 FT. |
| | DOORS. 2014 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, ADDITIONAL |
| | INFORMATION IS REQUIRED, DISCREPANCY IN PLANS. |
| | |
| | 6) SHEET A-1 AND A-4 THE NEW FRONT ENTRY SHOWS A |
| | EXISTING CONCRETE COLUMN. PLEASE SEE 2014 |
| | FBC-ACCESSIBILITY CODE FIGURE 404.2.4.1(A) THE REQUIRED |
| | MANEUVERING CLEARANCES, IT APPEARS THE EXISTING |
| | CONCRETE COLUMN WILL BE IN THE MANEUVERING CLEARANCES. |
| | PLEASE BE AWARE OF THE REQUIRED 42 INCHES REQUIRED FOR |
| | MANEUVERING CLEARANCES SEE FIGURE 404.2.4.1( K). |
| | |
| | 7) THE SUBMITTED ENERGY COMPLIANCE FORMS SUBMITTED ARE |
| | FORM 506-2010. PLEASE UPDATE FORMS TO THE 2014 |
| | FBC-ENERGY. |
| | |
| | |
| | 8) CHANGE IN OCCUPANCY: BEFORE A PERMIT TO CONSTRUCT, |
| | MAY BE ISSUED, IMPACT FEES MUST BE PAID TO PALM BEACH |
| | COUNTY. THE ACTUAL PERMIT SET OF PLANS MUST BE STAMPED |
| | BY THAT OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED |
| | TO THE PERMIT APPLICATION. PLEASE CALL (561)233-5025 |
| | FOR MORE INFORMATION. |
| | |
| | 9) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A |
| | RESULT OF THE ADDITIONAL INFORMATION REQUESTED |
| | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF |
| | THIS REVIEW. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |